MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/dcr.0000000000001084

Медицинская библиотека · Diseases of the colon and rectum · 2018

Three-Dimensional Modeling for Crohn's Fistula-in-Ano: A Novel, Interactive Approach.

Lam David, Yong Eric, D'Souza Basil, Woods Rodney

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pelvic MRI allows for clear delineation of anatomy in Crohn's fistula-in-ano, although its interpretation is often difficult for nonradiologists.

OBJECTIVE

The aim was to develop a 3-dimensional model where fistula tracts and their relationship to the sphincter complex can be accurately defined, which can then be rotated in multiple axes by the surgeon.

DESIGN

A 3-dimensional model was created based on MRI images. An additional 3-dimensional T2-weighted sequence was added to the existing MRI protocol to obtain high-resolution images. Segmentation of the fistula tract and volume rendering of the segmented tract were performed to create the final model.

SETTINGS: This was a single-center study conducted in Victoria, Australia.

PATIENTS: All of the patients who had pelvic MRI for fistulating Crohn's disease between March 2016 and March 2017 had the additional MRI sequence.

INTERVENTIONS: Postprocessing of MRI images was performed by a single radiologist.

RESULTS

Total acquisition time for MRI images was extended to 31 minutes compared with the standard 2-dimensional protocol lasting 25 minutes. Additional postprocessing time used to create the model was ≈15 minutes. Two clinical vignettes using this model are presented and compared with conventional 2-dimensional MRI images to highlight the use of the 3-dimensional modeling technique.

LIMITATIONS: This technique involves a semiautomatic process of fistula tract segmentation that requires radiologist expertise and additional postprocessing time.

CONCLUSIONS

This 3-dimensional modeling technique enables accurate identification of tracts in Crohn's fistula-in-ano and improves spatial orientation for the surgeon. The model has the potential to be an invaluable preoperative tool to guide operative decision-making, as well as enabling the assessment of response to medical or surgical therapy.

Для цитирования: Lam David, Yong Eric, D'Souza Basil, Woods Rodney. Three-Dimensional Modeling for Crohn's Fistula-in-Ano: A Novel, Interactive Approach.. Diseases of the colon and rectum. 2018. DOI: 10.1097/dcr.0000000000001084.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.