m+Medelevator.RU
← Поиск публикаций
CHEST pulmonary · 2025

The Additional Accuracy Gained by Cone Beam CT in Shape-Sensing Robotic Bronchoscopy.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Revelo Alberto E, Peng Jing, Ma Jianing, Woods Michael, Ghattas Christian, Pannu Jasleen, Horowitz Jeffrey C, Pastis Nicholas

Аннотация

BACKGROUND: Cone beam CT (CBCT) scan provides an intraprocedural 3-dimensional image of the biopsy tool in relation to the lesion, which may enhance the accuracy of robotic-assisted bronchoscopy (RAB) through real-time bronchoscopy adjustments. Our goal is to evaluate the ability to accurately position, in real time, a biopsy needle in the center of a pulmonary nodule using shape-sensing RAB alone vs shape-sensing RAB + CBCT guidance.

RESEARCH QUESTION: Does the addition of CBCT improve the accuracy of robotic bronchoscopy?

STUDY DESIGN AND METHODS: A total of 102 nodules were biopsied using shape-sensing RAB and the position of the needle in relation to the center of the nodule identified using a ceiling-mounted CBCT scanner. Repositioning of the RAB after 1 or 2 CBCT adjustments was accomplished using information gathered from the 3-dimensional images and using an updated augmented fluoroscopy target. The primary end point was needle location and distance change of the needle tip in reference to the lesion center using RAB alone vs RAB + CBCT scan. Secondary end points were improvement in radial endobronchial ultrasound image and average number of CBCT spins required to land at the center of the target.

RESULTS: Using RAB alone, the needle was placed in the center in 27 nodules (26.5%). The addition of CBCT scan to RAB greatly improved the distance of the needle toward the center of the lesion (mean ± SD, -4.08 ± 4.63 mm) in 46 nodules (61.3%) after 1 CBCT adjustment and (mean ± SD, -4.02 ± 4.21 mm) in an additional 17 nodules (58.6%) after a second CBCT adjustment (P < .001). Radial endobronchial ultrasound image was also improved from eccentric to concentric.

INTERPRETATION: The addition of CBCT scan to RAB was shown to improve the position of a biopsy tool in relation to the center of a pulmonary nodule. To our knowledge, this study is the first to quantify the accuracy achieved using both technologies, which may translate into reliability to perform diagnostic and potentially future therapeutic interventions in guided bronchoscopy.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты