Eye & contact lens · 2016
Use of Wavefront Imaging Technology to Demonstrate Improvement in Corneal Aberrations Using Piggyback Contact Lens in a Keratoconus Eye With Intrastromal Corneal Ring Segment Implantation: A Case Report.
Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kumar Mukesh, Shetty Rohit, Kumar Rajesh S, Nagaraj Sriharsha, Shetty Bhujang
Аннотация
OBJECTIVE: To quantify short-term changes in corneal high-order aberrations (HOA) with piggyback contact lens use in an eye with keratoconus that had undergone intrastromal ring segment (Intacs) implantation.
METHODS: A patient with keratoconus reporting of distorted images after Intacs surgery was found to have HOA (trefoil, point spread function [PSF], and modulation transfer function [MTF]) as measured using wavefront technology (Nidek OPD-Scan III) and evidenced by her cylindrical correction. She underwent piggyback contact lens (silicone hydrogel and fluoroperm rigid gas-permeable lenses) fitting in an attempt to improve the HOA.
RESULTS: After piggyback contact lens fitting, her visual acuity improved and all her visual symptoms resolved. High-order aberrations reduced from 3.152 to 0.490 after the lens fitting and was noted to be 0.447 at 6 months; trefoil also significantly improved (0.360-0.096; it was 0.031 at 6 months). The cylinder decreased from -4.50 to -0.75 and was stable at 6 months (-1.00). There was also significant improvement in PSF and MTF.
CONCLUSIONS: Visual acuity and symptoms along with HOA and cylinder improved after fitting of piggyback contact lens in our patient with keratoconus who had undergone Intacs.
METHODS: A patient with keratoconus reporting of distorted images after Intacs surgery was found to have HOA (trefoil, point spread function [PSF], and modulation transfer function [MTF]) as measured using wavefront technology (Nidek OPD-Scan III) and evidenced by her cylindrical correction. She underwent piggyback contact lens (silicone hydrogel and fluoroperm rigid gas-permeable lenses) fitting in an attempt to improve the HOA.
RESULTS: After piggyback contact lens fitting, her visual acuity improved and all her visual symptoms resolved. High-order aberrations reduced from 3.152 to 0.490 after the lens fitting and was noted to be 0.447 at 6 months; trefoil also significantly improved (0.360-0.096; it was 0.031 at 6 months). The cylinder decreased from -4.50 to -0.75 and was stable at 6 months (-1.00). There was also significant improvement in PSF and MTF.
CONCLUSIONS: Visual acuity and symptoms along with HOA and cylinder improved after fitting of piggyback contact lens in our patient with keratoconus who had undergone Intacs.