Use of Wavefront Imaging Technology to Demonstrate Improvement in Corneal Aberrations Using Piggyback Contact Lens in a Keratoconus Eye With Intrastromal Corneal Ring Segment Implantation: A Case Report.

Kumar Mukesh, Shetty Rohit, Kumar Rajesh S, Nagaraj Sriharsha, Shetty Bhujang

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To quantify short-term changes in corneal high-order aberrations (HOA) with piggyback contact lens use in an eye with keratoconus that had undergone intrastromal ring segment (Intacs) implantation.

METHODS

A patient with keratoconus reporting of distorted images after Intacs surgery was found to have HOA (trefoil, point spread function [PSF], and modulation transfer function [MTF]) as measured using wavefront technology (Nidek OPD-Scan III) and evidenced by her cylindrical correction. She underwent piggyback contact lens (silicone hydrogel and fluoroperm rigid gas-permeable lenses) fitting in an attempt to improve the HOA.

RESULTS

After piggyback contact lens fitting, her visual acuity improved and all her visual symptoms resolved. High-order aberrations reduced from 3.152 to 0.490 after the lens fitting and was noted to be 0.447 at 6 months; trefoil also significantly improved (0.360-0.096; it was 0.031 at 6 months). The cylinder decreased from -4.50 to -0.75 and was stable at 6 months (-1.00). There was also significant improvement in PSF and MTF.

CONCLUSIONS

Visual acuity and symptoms along with HOA and cylinder improved after fitting of piggyback contact lens in our patient with keratoconus who had undergone Intacs.

Для цитирования: Kumar Mukesh, Shetty Rohit, Kumar Rajesh S, Nagaraj Sriharsha, Shetty Bhujang. Use of Wavefront Imaging Technology to Demonstrate Improvement in Corneal Aberrations Using Piggyback Contact Lens in a Keratoconus Eye With Intrastromal Corneal Ring Segment Implantation: A Case Report.. Eye & contact lens. 2016. DOI: 10.1097/icl.0000000000000159.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.