MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2014.09.012

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2014

Which soft lens power is better for piggyback in keratoconus? Part II.

Romero-Jiménez Miguel, Santodomingo-Rubido Jacinto, González-Meijóme Jose-Manuel, Flores-Rodriguez Patricia, Villa-Collar Cesar

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate how soft lens power affects rigid gas-permeable (RGP) lens power and visual acuity (VA) in piggyback fittings for keratoconus.

METHODS

Sixteen keratoconus subjects (30 eyes) were included in the study. Piggyback contact lens fittings combining Senofilcon-A soft lenses of -6.00, -3.00, +3.00 and +6.00 D with Rose K2 RGP contact lenses were performed. Corneal topography was taken on the naked eye and over each soft contact lens before fitting RGP lenses. Mean central keratometry, over-refraction, RGP back optic zone radius (BOZR) and estimated final power as well as VA were recorded and analyzed.

RESULTS

In comparison to the naked eye, the mean central keratometry flattened with both negative lens powers (p<0.05 in all cases), did not change with the +3.00 soft lens power (p=1.0); and steepened with the +6.00 soft lens power (p=0.02). Rigid gas-permeable over-refraction did not change significantly between different soft lens powers (all p>0.05). RGP's BOZR decreased significantly with both positive in comparison with both negative soft lens powers (all p<0.001), but no significant differences were found among negative- or positive-powers separately (both p>0.05). Estimated RGP's final power increased significantly with positive in comparison with negative lens powers (all p<0.001), but no significant differences were found among negative or positive lens powers separately (both p>0.05). Visual acuity did not change significantly between the different soft lens powers assessed (all p>0.05).

CONCLUSION

The use of negative-powered soft lenses in piggyback fitting reduces RGP lens power without impacting VA in keratoconus subjects.

Для цитирования: Romero-Jiménez Miguel, Santodomingo-Rubido Jacinto, González-Meijóme Jose-Manuel, Flores-Rodriguez Patricia, Villa-Collar Cesar. Which soft lens power is better for piggyback in keratoconus? Part II.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2014. DOI: 10.1016/j.clae.2014.09.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.