Effects of corneal cross-linking on ocular response analyzer waveform-derived variables in keratoconus and postrefractive surgery ectasia.

Hallahan Katie M, Rocha Karolinne, Roy Abhijit S, Randleman J Bradley, Stulting R Doyle, Dupps William J

СтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: To assess changes in Ocular Response Analyzer (ORA) waveforms after UVA/riboflavin corneal collagen cross-linking (CXL) using investigator-derived and manufacturer-supplied morphometric variables in patients with keratoconus (KC) and postrefractive surgery ectasia.

DESIGN

Prospective randomized trial of a standard epithelium-off CXL protocol.

PARTICIPANTS

Patients with progressive KC (24 eyes of 21 patients) or postrefractive surgery ectasia (27 eyes of 23 patients) were enrolled.

METHODS

Replicate ORA measurements were obtained before and 3 months after CXL. Pretreatment and posttreatment waveform variables were analyzed for differences by paired Student t tests using measurements with the highest waveform scores.

MAIN OUTCOME MEASURES: Corneal hysteresis, corneal resistance factor, 37-s generation manufacturer-supplied ORA variables, and 15 investigator-derived ORA variables.

RESULTS

No variables were significantly different 3 months after CXL in the KC group, and no manufacturer-supplied variables changed significantly in the postrefractive surgery ectasia group. Four custom variables (ApplanationOnsetTime, P1P2avg, Impulse, and Pmax) increased by small but statistically significant margins after CXL in the postrefractive surgery ectasia group.

CONCLUSIONS

Changes in a small subset of investigator-derived variables suggested an increase in corneal bending resistance after CXL. However, the magnitudes of these changes were low and not commensurate with the degree of clinical improvement or prior computational estimates of corneal stiffening in the same cohort over the same period. Available air-puff-derived measures of the corneal deformation response underestimate the biomechanical changes produced by CXL.

Для цитирования: Hallahan Katie M, Rocha Karolinne, Roy Abhijit S, Randleman J Bradley, Stulting R Doyle, Dupps William J. Effects of corneal cross-linking on ocular response analyzer waveform-derived variables in keratoconus and postrefractive surgery ectasia.. Eye & contact lens. 2014. DOI: 10.1097/icl.0000000000000090.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.