Current eye research · 2014
Impact of Posterior Corneal Surface on Toric Intraocular Lens (IOL) Calculation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Preussner Paul-Rolf, Hoffmann Peter, Wahl Jochen
Аннотация
PURPOSE: To quantify the impact of posterior cornea on toric IOL calculation accuracy using Placido-topography of anterior corneal surface and Scheimpflug measurements of corneal thickness.
MATERIALS AND METHODS: Three-hundred seventy-nine non-selected eyes undergoing cataract surgery with non-toric intraocular lens (IOL) implantation were measured with TMS-5 (Tomey, Japan), IOLMaster (Zeiss, Germany) and Lenstar (Haag-Streit, Switzerland). Anterior, posterior and total measured corneal astigmatisms were compared with astigmatisms from postoperative refraction by calculating vector differences.
RESULTS: The average absolute vector difference between anterior astigmatism and total astigmatism combining the measurements of anterior and posterior cornea was only 0.3 ± 0.2 D, with a median of only 0.27 D, but a maximum of 1.5 D. Measurements of anterior cornea alone show a systematic difference from refractive cylinder of 0.3-6 D at 90, 0.38 D at 89° and 0.28 D at 91° (IOLMaster, Lenstar and anterior TMS5), whereas the total TMS5 cylinder differs on average by only 0.14D at 81° from the refractive cylinder. With-the-rule (WTR) corneal astigmatism is slightly reduced and against-the-rule (ATR) astigmatism slightly increased on average when posterior corneal surface is taken into account additionally. This could also be confirmed by the calculation of an average pachymetry of all eyes in which the thinnest central part shows an ellipsoidal shape with horizontally long axis.
CONCLUSION: Measurements of posterior cornea have on average only a small but significant impact on the outcome of toric IOL calculation, however, they are nevertheless recommended to detect outliers in which corneal irregularities (e.g. beginning keratokonus) may be overlooked.
MATERIALS AND METHODS: Three-hundred seventy-nine non-selected eyes undergoing cataract surgery with non-toric intraocular lens (IOL) implantation were measured with TMS-5 (Tomey, Japan), IOLMaster (Zeiss, Germany) and Lenstar (Haag-Streit, Switzerland). Anterior, posterior and total measured corneal astigmatisms were compared with astigmatisms from postoperative refraction by calculating vector differences.
RESULTS: The average absolute vector difference between anterior astigmatism and total astigmatism combining the measurements of anterior and posterior cornea was only 0.3 ± 0.2 D, with a median of only 0.27 D, but a maximum of 1.5 D. Measurements of anterior cornea alone show a systematic difference from refractive cylinder of 0.3-6 D at 90, 0.38 D at 89° and 0.28 D at 91° (IOLMaster, Lenstar and anterior TMS5), whereas the total TMS5 cylinder differs on average by only 0.14D at 81° from the refractive cylinder. With-the-rule (WTR) corneal astigmatism is slightly reduced and against-the-rule (ATR) astigmatism slightly increased on average when posterior corneal surface is taken into account additionally. This could also be confirmed by the calculation of an average pachymetry of all eyes in which the thinnest central part shows an ellipsoidal shape with horizontally long axis.
CONCLUSION: Measurements of posterior cornea have on average only a small but significant impact on the outcome of toric IOL calculation, however, they are nevertheless recommended to detect outliers in which corneal irregularities (e.g. beginning keratokonus) may be overlooked.