MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsami.6c10955

Медицинская библиотека · ACS applied materials & interfaces · 2026

Detection of Time-Dependent Uptake of Microplastics by Joint Utilization of Hepatic Organoids and a 3D-Printed Carrier.

Chen Hange, Zhou Yue, Wang Qianyi, Zhou Liujiang, Wang Yinyin, Xia Boyi, Li Yan, Feng Yan, Lei Dong, Wang Yan, Cheng Wei

СтатьяПеревод пока не подготовлен

Аннотация

Microplastics (MPs, <5 mm) are pervasive in foods, the environment, and humans, posing emerging health risks. Traditional two-dimensional (2D) cell models inadequately replicate micron-scale MP uptake, whereas three-dimensional (3D) organoids better mimic tissue complexity. Here, we developed a hepatic organoids (HOs)-in-cage system using human pluripotent stem cell-derived HOs and a 3D-printed porous poly(ε-caprolactone) carrier for efficient organoid retrieval. We established a label-free Nile Red (NR)-based spatiotemporal imaging and flow cytometric quantification pipeline to investigate the uptake dynamics and hepatotoxicity of UV-aged, size-mixed polypropylene (PP, 1 to 20 μm), as well as to colocalize the MP and potential biomarkers within HOs. Contrary to 2D models where >5 μm particles show negligible internalization, 3D HOs exhibited significant accumulation of intact micron-scale MPs via tissue-layer penetration and paracellular retention, with PP uptake peaking at ∼40% within 48 h and ∼18% retained long-term. This triggered dose- and time-dependent hepatotoxicity (40-4000 ng/mL), marked by CD36 upregulation from 8 h, mitochondrial impairment, and elevated LDH and AST levels. Notably, NR fluorescence intensity was governed by polymer chemistry rather than surface roughness, enabling material-specific detection. This work provides novel label-free techniques within 3D in vitro models to explore the depot and effective concentration of micron-scale MPs, advancing understanding of MP-induced cellular damage upon uptake and deposition.

Для цитирования: Chen Hange, Zhou Yue, Wang Qianyi, Zhou Liujiang, Wang Yinyin, Xia Boyi, Li Yan, Feng Yan, Lei Dong, Wang Yan, Cheng Wei. Detection of Time-Dependent Uptake of Microplastics by Joint Utilization of Hepatic Organoids and a 3D-Printed Carrier.. ACS applied materials & interfaces. 2026. DOI: 10.1021/acsami.6c10955.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.