Transvenous Before Surgical Hybrid Procedure.
Аннотация
BACKGROUND
Historically, persistent atrial fibrillation (PeAF) and long standing persistent atrial fibrillation (LSPeAF) have demonstrated limited clinical success despite hybrid approaches.
OBJECTIVE
We describe our experience with the endocardial-before-epicardial approach defined by a comprehensive endovascular approach preceding and guiding the epicardial approach which includes an extensive posterior wall ablation.
METHODS
40 patients were followed over a 12 month period. The procedure was performed in a single center. Patients had a mean duration of atrial fibrillation of 6.0 ± 4.5 years with 22.5% having undergone prior ablations. Mean age was 61.7 ± 7.9 years with a mean left atrial volume of 131.5 ± 46.9 mL. The endovascular procedure remained uniform with antral pulmonary vein isolation, posterior left atrial roof and right atrial cavo-tricuspid isthmus (CTI) linear lesions with mapping and ablation of left atrial complex electrograms (CFAEs) and prior existing atrial arrhythmias. The epicardial procedure included a thorascopic approach with ganglionated plexus (GP) mapping and ablation, left atrial posterior wall ablation, directed CFAE ablation and left atrial appendage ligation. All patients received implantable cardiac monitoring.
RESULTS
All 40 patients remained in sinus rhythm at their 12 month follow-up. During the monitoring period, episodes of paroxysmal atrial arrhythmias including fibrillation were documented, without persistence, after discontinuation of oral antiarrhythmic medications.
CONCLUSION
The endo-before-epi approach resulted in improved management of persistent and long standing persistent atrial fibrillation over reported results for conventional approaches with no procedural complications, making this a promising option for the management of these arrhythmias.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.