Repetitive atrial activation during ongoing atrial fibrillation-comparison using different mapping algorithms: preliminary findings.

Halbfass Philipp, Müller Patrick, Nentwich Karin, Sonne Kai, Hamm Karsten, Barth Sebastian, Fochler Franziska, Mügge Andreas, Deneke Thomas

Клинический случайСравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Targeting repetitive sources identified during atrial fibrillation (focal impulse and rotor modulation, FIRM) has been used as an ablation strategy using specific mapping tools. Aim of this study was to evaluate FIRM mapped rotors with a new multipolar mapping algorithm.

METHODS

Patients with persistent atrial fibrillation undergoing FIRM ablation were included. Mapping of left atrial rotors was performed with a 64-pole basket catheter in conjunction with a specialized phase mapping algorithm. Subsequently, raw signals were analyzed by a novel mapping system (CARTOFINDER™). Comparison of FIRM identified sources with areas of repetitive activation analyzed by CARTOFINDER™ was performed.

RESULTS

Nine patients were included (5 redo procedures; male n = 6; 66.5 ± 8.6 years) and 28 left atrial rotors were compared with the findings of the novel mapping system. CARTOFINDER™ identified repetitive activation patterns in 6 mapping sequences at remote sites (2 rotational patterns, 4 linear activation patterns).

CONCLUSIONS

In this comparative preliminary study, two different mapping technologies to detect repetitive atrial activation during ongoing AF were used. Whereas rotational activation was documented using FIRM mapping no corresponding repetitive activation patterns near sites of FIRM-mapped rotor cores were identified using the novel mapping technology even though using the same electrogram characteristics and mapping basket position.

Для цитирования: Halbfass Philipp, Müller Patrick, Nentwich Karin, Sonne Kai, Hamm Karsten, Barth Sebastian, Fochler Franziska, Mügge Andreas, Deneke Thomas. Repetitive atrial activation during ongoing atrial fibrillation-comparison using different mapping algorithms: preliminary findings.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2017. DOI: 10.1007/s10840-017-0244-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.