Circulation journal : official journal of the Japanese Circulation Society · 2017
Three-Year Clinical Outcome After 2nd-Generation Cryoballoon-Based Pulmonary Vein Isolation for the Treatment of Paroxysmal and Persistent Atrial Fibrillation - A 2-Center Experience.
Клиническое исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Heeger Christian-H, Wissner Erik, Knöll Milena, Knoop Benedikt, Reissmann Bruno, Mathew Shibu, Sohns Christian, Lemes Christine, Maurer Tilman, Santoro Francesco, Riedl Johannes, Inaba Osamu, Fink Thomas, Rottner Laura, Wohlmuth Peter, Goldmann Britta, Ouyang Feifan, Kuck Karl-Heinz, Metzner Andreas
Аннотация
BACKGROUND: Pulmonary vein isolation (PVI) using the 2nd-generation cryoballoon (CB2) for the treatment of atrial fibrillation (AF) has demonstrated encouraging acute and mid-term results. However, follow-up data on outcomes beyond 1 year are sparse. We investigated the 3-year outcome after PVI using the CB2.
METHODS AND RESULTS: 100 patients with paroxysmal (PAF, 70/100 [70%] patients) or persistent AF (pAF, 30/100 [30%] patients) underwent CB2-based PVI in 2 experienced centers in Germany. Freeze-cycle duration was 240 s. After successful PVI a bonus freeze-cycle of the same duration was applied in the first 71 patients but was omitted in the following 29 patients. Phrenic nerve palsy occurred in 3 patients (3%); 2 patients were lost to follow-up. After a median follow-up of 38 (29-50) months, 59/98 (60.2%) patients remained in stable sinus rhythm (PAF: 48/70 (69%), pAF: 11/28 (39%) P=0.0084). In 32/39 (77%) patients with arrhythmia recurrence, a second ablation procedure using radiofrequency energy was conducted. Persistent PVI was noted in 76/125 (61%) PVs. After a mean of 1.37±0.6 procedures and a median follow-up of 35 (25-39) months, 77/98 (78.6%) patients remained in stable sinus rhythm (PAF: 56/70 (80%), pAF: 20/28 (71%), P=0.0276).
CONCLUSIONS: CB2-based PVI resulted in a 60.2% single-procedure and a 78.6% multiple-procedure success rate after 3 years. Repeat procedures demonstrated a high rate of durable PVI.
METHODS AND RESULTS: 100 patients with paroxysmal (PAF, 70/100 [70%] patients) or persistent AF (pAF, 30/100 [30%] patients) underwent CB2-based PVI in 2 experienced centers in Germany. Freeze-cycle duration was 240 s. After successful PVI a bonus freeze-cycle of the same duration was applied in the first 71 patients but was omitted in the following 29 patients. Phrenic nerve palsy occurred in 3 patients (3%); 2 patients were lost to follow-up. After a median follow-up of 38 (29-50) months, 59/98 (60.2%) patients remained in stable sinus rhythm (PAF: 48/70 (69%), pAF: 11/28 (39%) P=0.0084). In 32/39 (77%) patients with arrhythmia recurrence, a second ablation procedure using radiofrequency energy was conducted. Persistent PVI was noted in 76/125 (61%) PVs. After a mean of 1.37±0.6 procedures and a median follow-up of 35 (25-39) months, 77/98 (78.6%) patients remained in stable sinus rhythm (PAF: 56/70 (80%), pAF: 20/28 (71%), P=0.0276).
CONCLUSIONS: CB2-based PVI resulted in a 60.2% single-procedure and a 78.6% multiple-procedure success rate after 3 years. Repeat procedures demonstrated a high rate of durable PVI.