The incremental benefit of non-pulmonary vein left atrial ablation in patients undergoing a repeat persistent atrial fibrillation ablation procedure.
Аннотация
PURPOSE: Atrial fibrillation (AF) recurrence after an initial persistent AF ablation procedure is high, frequently resulting in the need for a repeat AF ablation procedure. Guidance on the optimal strategy for repeat procedures is non-existent. The objective of this study was to compare the freedom from recurrent atrial arrhythmia associated with two strategies for repeat persistent AF ablation procedure: (1) pulmonary vein re-isolation alone and (2) non-pulmonary vein LA ablation in addition to pulmonary vein re-isolation.
METHODS
A retrospective multi-center case-controlled study was undertaken. Time-to-recurrent AF with each strategy was assessed using Kaplan-Meier curves. A Cox proportional-hazards regression model was used to determine time-dependent predictors of recurrent AF after the repeat procedure in the entire cohort.
RESULTS
Ninety-eight patients were included in the cohort-39 patients who did not undergo additional LA ablation and 59 patients who had did. AF after the repeat procedure occurred in 38 % of the cohort during a mean follow-up of 18 ± 11 months. Additional LA ablation at the repeat procedure was not associated with a less arrhythmia recurrence (HR = 1.55, p = 0.28). The only variable associated with arrhythmia recurrence after the repeat procedure was additional LA ablation during the initial ablation procedure (HR = 4.13, p = 0.005).
CONCLUSIONS
LA ablation in addition to pulmonary vein re-isolation during a repeat persistent AF ablation procedure was not associated with reduced arrhythmia recurrence after a repeat persistent AF ablation procedure.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.