Huemer Martin, Qaiyumi Daniel, Attanasio Philipp, Parwani Abdul, Pieske Burkert, Blaschke Florian, Boldt Leif-Hendrik, Haverkamp Wilhelm, Wutzler Alexander
Аннотация
AIMS: In persistent atrial fibrillation (AF), left atrial low-voltage areas and complex fractionated atrial electrograms (CFAEs) have been thoroughly discussed as critical substrate points for AF perpetuation. Thus, in patients undergoing pulmonary vein isolation, these sites are often considered additional ablation targets. Currently, mapping techniques for these substrate indicators are still under discussion. The aim of this study was to evaluate the impact of different mapping catheters on the detection of low-voltage areas and CFAE.
METHODS AND RESULTS: Two bipolar voltage maps and two CFAE left atrial maps were obtained each in 30 patients undergoing catheter ablation of AF using the following two different catheters: A four-pole ablation catheter (MAP, mapping and ablation catheter) (electrode size: tip: 4 mm, band: 1 mm; inter-electrode spacing: 0.5-5-2 mm) and a 10-pole circular pulmonary vein mapping catheter (CMC) (electrode size: 1 mm; inter-electrode spacing: 7-7-7 mm). Successively, low-voltage and CFAE area sizes were then compared between the two catheters. Areas with a bipolar voltage of <0.5 mV were significantly smaller when obtained with the CMC compared with the MAP (8.9 ± 8.9 vs. 17.4 ± 11.7 cm², P < 0.001). This was also significantly different for a bipolar voltage of <0.2 mV (2.3 ± 4.6 vs. 6.2 ± 9.6 cm², P < 0.001). Complex fractionated atrial electrogram area sizes were significantly larger when obtained with the CMC compared with the MAP group (14.6 ± 10.9 vs. 19.4 ± 9.4 cm², P = 0.011).
CONCLUSION: Low-voltage and CFAE area size varies significantly between different mapping catheters. Mapping electrode settings have to be taken into consideration for the assessment of electroanatomical substrate of AF.
METHODS AND RESULTS: Two bipolar voltage maps and two CFAE left atrial maps were obtained each in 30 patients undergoing catheter ablation of AF using the following two different catheters: A four-pole ablation catheter (MAP, mapping and ablation catheter) (electrode size: tip: 4 mm, band: 1 mm; inter-electrode spacing: 0.5-5-2 mm) and a 10-pole circular pulmonary vein mapping catheter (CMC) (electrode size: 1 mm; inter-electrode spacing: 7-7-7 mm). Successively, low-voltage and CFAE area sizes were then compared between the two catheters. Areas with a bipolar voltage of <0.5 mV were significantly smaller when obtained with the CMC compared with the MAP (8.9 ± 8.9 vs. 17.4 ± 11.7 cm², P < 0.001). This was also significantly different for a bipolar voltage of <0.2 mV (2.3 ± 4.6 vs. 6.2 ± 9.6 cm², P < 0.001). Complex fractionated atrial electrogram area sizes were significantly larger when obtained with the CMC compared with the MAP group (14.6 ± 10.9 vs. 19.4 ± 9.4 cm², P = 0.011).
CONCLUSION: Low-voltage and CFAE area size varies significantly between different mapping catheters. Mapping electrode settings have to be taken into consideration for the assessment of electroanatomical substrate of AF.
Предметные рубрики MeSH
Action PotentialsAgedAtrial FibrillationCardiac CatheterizationCardiac CathetersCatheter AblationElectrophysiologic Techniques, CardiacEquipment DesignFemaleHeart RateHumansMaleMiddle AgedPredictive Value of TestsProspective StudiesPulmonary VeinsReproducibility of ResultsSignal Processing, Computer-Assisted