MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2021.101499

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2021

Tear film interferometry assessment after intense pulsed light in dry eye disease: A randomized, single masked, sham-controlled study.

Song Yilin, Yu Sile, He Xingru, Yang Lanting, Wu Yi, Qin Guanghao, Zhang Qing, Deep Singh Talwar Gagan, Xu Ling, Moore Jonathan E, He Wei, Pazo Emmanuel Eric

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Inadequate meibomian glands (MGs) secretion can lead to dry eye signs and symptoms. Tear film lipid layer (TFLL) secreted by MGs protects and prevents rapid evaporation of tear film. The purpose was to assess TFLL alteration and function in patients with evaporative dry eye (EDE) using tear interferometry after optimal pulse light technology (OPT) intense pulsed light (IPL).

METHODS

This prospective randomized examiner-masked sham- controlled study included 86 participants (142 eyes) with DED. IPL or sham procedure was performed on day 0, 21, and 42. Ocular Surface Disease Index (OSDI), non-invasive breakup time (NITBUT), interferometric fringe pattern determined TFLL quality, fluorescein staining (FS), and meibum gland (MG) were assessed at day 0, 21, 42 and 3-month.

RESULTS

At 3-month, TFLL, NITBUT, MG drop-out, MG quality, MG expressibility, FS and OSDI improved significantly (P < 0.05) in the IPL group, while the sham group had no significant improvements. Except for Meibo-score and FS, all parameters significantly correlated with the improvement in TFLL following IPL treatment. Additionally, artificial tears usage was significantly less in the IPL group from D-42 onwards.

CONCLUSION

IPL treatment demonstrated the ability to improve TFLL quality and clinically reduced sign and symptoms of DED thereby reducing the frequency of artificial tears use.

Для цитирования: Song Yilin, Yu Sile, He Xingru, Yang Lanting, Wu Yi, Qin Guanghao, Zhang Qing, Deep Singh Talwar Gagan, Xu Ling, Moore Jonathan E, He Wei, Pazo Emmanuel Eric. Tear film interferometry assessment after intense pulsed light in dry eye disease: A randomized, single masked, sham-controlled study.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2021. DOI: 10.1016/j.clae.2021.101499.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.