m+Medelevator.RU
← Поиск публикаций
Biomedical physics & engineering express · 2024

Segmentation of bone surface from ultrasound using a lightweight network UBS-Net.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Peng Fan, Zhang Yunxian, Cui Shangqi, Wang Binbin, Wang Dan, Shi Zhe, Li Lanlin, Fang Xiutong, Yang Zhi

Аннотация

Objective. Ultrasound-assisted orthopaedic navigation held promise due to its non-ionizing feature, portability, low cost, and real-time performance. To facilitate the applications, it was critical to have accurate and real-time bone surface segmentation. Nevertheless, the imaging artifacts and low signal-to-noise ratios in the tomographical B-mode ultrasound (B-US) images created substantial challenges in bone surface detection. In this study, we presented an end-to-end lightweight US bone segmentation network (UBS-Net) for bone surface detection.Approach. We presented an end-to-end lightweight UBS-Net for bone surface detection, using the U-Net structure as the base framework and a level set loss function for improved sensitivity to bone surface detectability. A dual attention (DA) mechanism was introduced at the end of the encoder, which considered both position and channel information to obtain the correlation between the position and channel dimensions of the feature map, where axial attention (AA) replaced the traditional self-attention (SA) mechanism in the position attention module for better computational efficiency. The position attention and channel attention (CA) were combined with a two-class fusion module for the DA map. The decoding module finally completed the bone surface detection.Main Results. As a result, a frame rate of 21 frames per second (fps) in detection were achieved. It outperformed the state-of-the-art method with higher segmentation accuracy (Dice similarity coefficient: 88.76% versus 87.22%) when applied the retrospective ultrasound (US) data from 11 volunteers.Significance. The proposed UBS-Net for bone surface detection in ultrasound achieved outstanding accuracy and real-time performance. The new method out-performed the state-of-the-art methods. It had potential in US-guided orthopaedic surgery applications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты