m+Medelevator.RU
← Поиск публикаций
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2016

Procedural characteristics of pulmonary vein isolation using the novel third-generation cryoballoon.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fürnkranz Alexander, Bologna Fabrizio, Bordignon Stefano, Perrotta Laura, Dugo Daniela, Schmidt Boris, Chun Julian K R

Аннотация

AIM: A novel third-generation cryoballoon (CB3) to perform pulmonary vein isolation (PVI) has recently been released, featuring a shortened distal balloon tip when compared with the second-generation (CB2), possibly allowing for enhanced intra-ablation pulmonary vein (PV) signal mapping. We aimed to investigate procedural efficacy and safety of the CB3 as compared to the CB2.

METHODS AND RESULTS: We studied 472 consecutive patients who underwent CB-PVI for paroxysmal or persistent atrial fibrillation (CB3: 49 patients; CB2: 423 patients). Detailed procedural data and in-hospital complications were registered in a prospective database. Complete PVI using the CB only was achieved in 98% of patients in each group. Single-freeze PVI was observed in 84/88% (CB2/CB3, P = n.s.) of the PVs. Time-to-PVI (TPVI) was 49 ± 32 (CB2) and 45 ± 27 s (CB3) (P = n.s.). Time-to-PVI determination rate was higher in the CB3 group (89.5 vs. 82.6%, P = 0.016). Signal noise due to ice formation on mapping electrodes occurred after 70 ± 46 s using CB3 and did not interfere with TPVI determination. Exchange of the spiral mapping catheter with a guide wire was more frequently required in the CB3 group (8.2 vs. 0.7% patients, P < 0.001). Balloon dislodgement during hockey stick manoeuvres occurred in 6.1% patients of the CB3 group only (P = 0.001). Complication rates were not different between the groups.

CONCLUSION: The CB3 offers a higher TPVI determination rate, facilitating dosing schemes based on TPVI, with equally high single-freeze efficacy compared with the CB2. The shortened distal tip of the CB3 requires adaptation of standard catheter manoeuvers to avoid balloon dislodgement.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты