DOI 10.1016/j.hrthm.2016.02.007

Медицинская библиотека · Heart rhythm · 2016

Electrophysiological findings after surgical thoracoscopic atrial fibrillation ablation.

Osmancik Pavel, Budera Petr, Zdarska Jana, Herman Dalibor, Petr Robert, Straka Zbynek

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Hybrid ablation (a combination of thoracoscopic epicardial ablation and catheter ablation) has become a new technique for atrial fibrillation treatment.

OBJECTIVE

The goal of this study was to evaluate the success and electrophysiological follow-up after using the COBRA Fusion device to deliver a circumferential lesion set anterior to the pulmonary veins in an attempt to isolate the posterior left atrium (box isolation).

METHODS

Surgical ablation was carried out via a thoracoscopic approach using the COBRA Fusion radiofrequency catheter. An electrophysiology study was done 2-3 months later to verify box isolation (and to complete it, if needed) and to perform right-sided isthmus ablation. Fat thickness along the presumed box lesion line was measured using preprocedural computed tomography.

RESULTS

Thirty patients (mean age 60.0 ± 11.6 years; 22 men; 8 with long-standing persistent AF and 22 with persistent atrial fibrillation) were enrolled. The duration of the EP study was 216.3 ± 64.2 minutes. Box isolation, based on the EP study, was complete in 12 patients (40%) and incomplete in 18 patients (60%). Successful box isolation was achieved with catheter ablation in 16 of 18 patients (89%). A total of 39 gaps in these 16 patients were identified. Typical gap locations were the anterior-superior part of the superior pulmonary veins and the roofline. Fat thickness along the roofline was substantially higher than that along the inferior line (4.58 ± 1.61 mm vs 2.37 ± 0.76 mm; P < .001).

CONCLUSION

There is a relatively low rate of complete isolation using the COBRA catheter ablation system. The superior line and anterior parts of superior pulmonary veins have most conduction gaps.

Для цитирования: Osmancik Pavel, Budera Petr, Zdarska Jana, Herman Dalibor, Petr Robert, Straka Zbynek. Electrophysiological findings after surgical thoracoscopic atrial fibrillation ablation.. Heart rhythm. 2016. DOI: 10.1016/j.hrthm.2016.02.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.