MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.115.003354

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2016

Atrial Fibrillation Complexity Parameters Derived From Surface ECGs Predict Procedural Outcome and Long-Term Follow-Up of Stepwise Catheter Ablation for Atrial Fibrillation.

Lankveld Theo, Zeemering Stef, Scherr Daniel, Kuklik Pawel, Hoffmann Boris A, Willems Stephan, Pieske Burkert, Haïssaguerre Michel, Jaïs Pierre, Crijns Harry J, Schotten Ulrich

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The success rate of catheter ablation for persistent atrial fibrillation (AF) is still far from satisfactory. Identification of patients who will benefit from ablation is highly desirable. We investigated the predictive value of noninvasive AF complexity parameters derived from standard 12-lead ECGs for AF termination and long-term success of catheter ablation and compared them with clinical predictors.

METHODS AND

RESULTS

The study included a training (93 patients) and a validation set (81 patients) of patients with persistent AF undergoing stepwise radiofrequency ablation. In the training set AF terminated in 81% during catheter ablation, 77% were in sinus rhythm after 6 years and multiple ablations. ECG-derived complexity parameters were determined from a baseline 10-s 12-lead ECG. Prediction of AF termination was similar using only ECG (cross-validated mean area under the curve [AUC], 0.76±0.15) or only clinical parameters (mean AUC, 0.75±0.16). The combination improved prediction to a mean AUC of 0.79±0.13. Using a combined model of ECG and clinical parameters, sinus rhythm at long-term follow-up could be predicted with a mean AUC of 0.71±0.12. In the validation set AF terminated in 57%, 61% were in sinus rhythm after 4.6 years. The combined models predicted termination with an AUC of 0.70 and sinus rhythm at long-term follow-up with an AUC of 0.61. Overall, fibrillation-wave amplitude provided the best rhythm prediction.

CONCLUSIONS

The predictive performance of ECG-derived AF complexity parameters for AF termination and long-term success of catheter ablation in patients with persistent AF is at least as good as known clinical predictive parameters, with fibrillation-wave amplitude as the best predictor.

Для цитирования: Lankveld Theo, Zeemering Stef, Scherr Daniel, Kuklik Pawel, Hoffmann Boris A, Willems Stephan, Pieske Burkert, Haïssaguerre Michel, Jaïs Pierre, Crijns Harry J, Schotten Ulrich. Atrial Fibrillation Complexity Parameters Derived From Surface ECGs Predict Procedural Outcome and Long-Term Follow-Up of Stepwise Catheter Ablation for Atrial Fibrillation.. Circulation. Arrhythmia and electrophysiology. 2016. DOI: 10.1161/circep.115.003354.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.