m+Medelevator.RU
← Поиск публикаций
Clinical oral investigations · 2024

Does the universal adhesive's film thickness affect dentin-bonding effectiveness?

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tang Chuliang, Mercelis Ben, Yoshihara Kumiko, Peumans Marleen, Van Meerbeek Bart

Аннотация

OBJECTIVES: To investigate the influence of adhesive resin application modalities on the film thickness of the adhesive resin and the effectiveness of a two-step universal adhesive (UA) bonded in self-etch (SE) bonding mode to high C-factor class-I cavity-bottom dentin.

MATERIALS AND METHODS: After application of the primer of G2-Bond Universal (G2B, GC), the adhesive resin was applied into standard class-I cavities (human molars) following four application modalities: (1) one layer, strongly air-blown; (2) one layer, gently air-blown; (3) two layers, each gently air-blown; (4) one layer, not air-blown. After being restored with composite, each tooth was sectioned to obtain one micro-specimen (n = 10), of which the adhesive resin film thickness was measured using optical microscopy. The micro-tensile bond strength (μTBS) was tested immediately or upon 100,000 thermocycles. Statistical analyses involved Kruskal-Wallis and Mann-Whitney U testing (p < 0.05).

RESULTS: G2B's μTBS was significantly affected by the adhesive resin application modality and aging. Gently air-blowing the adhesive resin resulted in significantly higher immediate μTBS than strong air-blowing or no air-blowing. No significant difference in μTBS was found between single or double gently air-blown adhesive resin applications. The adhesive resin film thickness significantly varied with the application modalities.

CONCLUSIONS: A too thin or too thick adhesive resin film thickness adversely affected bond strength of the two-step UA applied in SE mode and high C-factor condition.

CLINICAL RELEVANCE: The adhesive resin layer thickness can affect the bonding performance of two-step UAs in high C-factor cavities. Dental clinicians remain advised to avoid improper air-blowing of UAs and strictly follow the application instructions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты