DOI 10.1007/s00784-024-05523-7

Медицинская библиотека · Clinical oral investigations · 2024

Does the universal adhesive's film thickness affect dentin-bonding effectiveness?

Tang Chuliang, Mercelis Ben, Yoshihara Kumiko, Peumans Marleen, Van Meerbeek Bart

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To investigate the influence of adhesive resin application modalities on the film thickness of the adhesive resin and the effectiveness of a two-step universal adhesive (UA) bonded in self-etch (SE) bonding mode to high C-factor class-I cavity-bottom dentin.

MATERIALS AND

METHODS

After application of the primer of G2-Bond Universal (G2B, GC), the adhesive resin was applied into standard class-I cavities (human molars) following four application modalities: (1) one layer, strongly air-blown; (2) one layer, gently air-blown; (3) two layers, each gently air-blown; (4) one layer, not air-blown. After being restored with composite, each tooth was sectioned to obtain one micro-specimen (n = 10), of which the adhesive resin film thickness was measured using optical microscopy. The micro-tensile bond strength (μTBS) was tested immediately or upon 100,000 thermocycles. Statistical analyses involved Kruskal-Wallis and Mann-Whitney U testing (p < 0.05).

RESULTS

G2B's μTBS was significantly affected by the adhesive resin application modality and aging. Gently air-blowing the adhesive resin resulted in significantly higher immediate μTBS than strong air-blowing or no air-blowing. No significant difference in μTBS was found between single or double gently air-blown adhesive resin applications. The adhesive resin film thickness significantly varied with the application modalities.

CONCLUSIONS

A too thin or too thick adhesive resin film thickness adversely affected bond strength of the two-step UA applied in SE mode and high C-factor condition.

CLINICAL RELEVANCE: The adhesive resin layer thickness can affect the bonding performance of two-step UAs in high C-factor cavities. Dental clinicians remain advised to avoid improper air-blowing of UAs and strictly follow the application instructions.

Для цитирования: Tang Chuliang, Mercelis Ben, Yoshihara Kumiko, Peumans Marleen, Van Meerbeek Bart. Does the universal adhesive's film thickness affect dentin-bonding effectiveness?. Clinical oral investigations. 2024. DOI: 10.1007/s00784-024-05523-7.