MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.12791

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2016

Improvement of Atrial and Ventricular Remodeling with Low Atrial Fibrillation Burden after Hybrid Ablation of Persistent Atrial Fibrillation.

Toplisek Janez, Pernat Andrej, Ruzic Nada, Robic Boris, Sinkovec Matjaz, Cvijic Marta, Gersak Borut

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

An endoscopic transdiaphragmatic epicardial radiofrequency ablation procedure combined with percutaneous endocardial radiofrequency ablation--a hybrid procedure--is a potentially curative treatment option for patients with persistent atrial fibrillation (AF). Long-term effects of arrhythmia elimination on atrial and ventricular remodeling are not completely understood. Therefore, the aim of our study was to quantify echocardiographic structural and functional changes of the left atrium (LA) and left ventricle (LV) following a hybrid procedure.

METHODS AND

RESULTS

Thirty-seven consecutive patients with symptomatic drug refractory persistent AF underwent a hybrid procedure to achieve complete pulmonary vein and LA posterior wall electrical isolation. AF burden was measured using an insertable electrocardiographic (ECG) monitor. Patients were divided into responders to ablation and nonresponders according to postoperative AF burden at 12-month follow-up (responder < 0.5% vs nonresponder ≥ 0.5%). Median AF burden was 0.32 (0.04-27.5)% for all patients. In responders (19/37 patients), significant echocardiographic reduction of LA volume index from 47 to 41 mL/m(2) (P < 0.05) and improvement of LA function parameters (LA stiffness from 73.3 to 41.3 [P < 0.05], LA emptying fraction from 21% to 45% [P < 0.05], LA global longitudinal strain from 11.2% to 18.8% [P < 0.5]) was documented. In addition, LV systolic function significantly improved in comparison with nonresponders.

CONCLUSION

Hybrid ablation of persistent AF achieved stable sinus rhythm in a significant proportion of patients, as evidenced by continuous ECG monitoring, resulting in important LA and LV reverse remodeling after 12 months.

Для цитирования: Toplisek Janez, Pernat Andrej, Ruzic Nada, Robic Boris, Sinkovec Matjaz, Cvijic Marta, Gersak Borut. Improvement of Atrial and Ventricular Remodeling with Low Atrial Fibrillation Burden after Hybrid Ablation of Persistent Atrial Fibrillation.. Pacing and clinical electrophysiology : PACE. 2016. DOI: 10.1111/pace.12791.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.