MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Pakistan journal of medical sciences · 2014

The effects of 21 and 23 milimeter aortic valve prosthesis on hemodynamic performance and functional capacity in young adults.

Yener Ali Umit, Ozcan Sedat, Budak Ali Baran, Genc Serhat Bahadir, Ozkan Turgut, Cicek Omer Faruk

СтатьяОтозванная публикацияПеревод в очереди
Источник пометил публикацию как отозванную.

Аннотация

OBJECTIVE

Early and medium-term improvement of functional capacity and regression of left ventricular hypertrophy was evaluated in the young adult patient group following application of 21 mm or 23 mm bileaflet aortic mechanical valve prosthesis due to aortic stenosis.

Methods

Twenty two patients (10 male, 12 female; mean age 27+-8.2 (19-43)) who underwent isolated aortic valve replacement due to rheumatic aortic stenosis, were included in the study. 21 mm and 23 mm bileaflet mechanical prosthesis was used respectively in eight and fourteen patients. The mean body surface area was 1.86 m(2) and 1.68 m(2) respectively in 23 mm and 21 mm prosthesis while 1.73 ±0.25 m(2) for the whole group. Functional capacity was New York Heart Association (NYHA) class II in 9 patients and class III in thirteen patients. Implantation was performed without enlarging the aortic root in all except four patients. In all patients transvalvular gradients, effective orifice area and the diameter of left ventricle were measured with transthoracic echocardiography during rest and after maximal exercise. Mean follow-up was 34±12 months (range 11-57 months).

RESULTS

There were no postoperative complications or deaths. All the patients were assessed as NYHA class I with regards to functional capacity (p=0.01). Significant improvements were determined in postoperative mean transvalvular gradient (p=0.005) and left ventricular mass index (p=0.01) when compared with preoperative values.

CONCLUSION

Our findings show that replacement with 21 mm and 23 mm mechanical prosthesis provides a significant improvement in regression of symptoms and increase of functional capacity in young adults in early and mid-period without increasing mortality and morbidity.

Для цитирования: Yener Ali Umit, Ozcan Sedat, Budak Ali Baran, Genc Serhat Bahadir, Ozkan Turgut, Cicek Omer Faruk. The effects of 21 and 23 milimeter aortic valve prosthesis on hemodynamic performance and functional capacity in young adults.. Pakistan journal of medical sciences. 2014.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.