MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bcp.2025.117115

Медицинская библиотека · Biochemical pharmacology · 2025

Nanosystems for myocardial ischemic injury theranostics.

Žulpaitė Ugnė, Petrikaitė Vilma

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Early ischemia detection and effective treatment are crucial to reduce the risk of further complications. For diagnosing ischemic heart disease (IHD), ultrasound, magnetic resonance or computer tomography imaging is often used. However, each IHD diagnostic method has its own drawbacks, for example, the image of an ultrasound examination cannot be reproduced, the quality of the image itself may differ, the magnetic resonance examination requires a longer scanning time and is contraindicated for people with a pacemaker while computed tomography may have a low resolution. Recently, contrast agents have been utilised in clinical settings to improve ultrasound examination images. Nevertheless, the limitations linked to these agents motivate researchers to investigate alternative materials for enhancing image contrast. One example of such constructs could be nanoformulations. Studies show that nanoparticles are promising not only in the visualisation of damaged myocardium but also in therapy. Studies conducted in vivo demonstrate that incorporating cardiological drugs into nanoparticles can enhance their pharmacokinetic, physical, or even chemical characteristics. Targeted nanotherapy has gained considerable attention, involving the attachment of various peptides or ligands to the surface of nanoparticles, which bind to specific cell targets. While many studies are conducted under in vivo conditions, developing new nanoparticles to refine in vitro testing methodologies is crucial. This step is necessary to preclude inefficient compounds from advancing to preclinical animal studies, thus mitigating research costs.

Для цитирования: Žulpaitė Ugnė, Petrikaitė Vilma. Nanosystems for myocardial ischemic injury theranostics.. Biochemical pharmacology. 2025. DOI: 10.1016/j.bcp.2025.117115.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.