MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/08869634.2000.11746110

Медицинская библиотека · Cranio : the journal of craniomandibular practice · 2000

Effects of a single and double commercial athletic mouthpiece on expiratory peak flow: a pilot study.

Schwartz R, Collins B J, Fong C

СтатьяПеревод пока не подготовлен

Аннотация

Utilizing an Assess Peak Flow Meter, six healthy subjects with no lung disease volunteered to have their expiratory peak flow measured under the following five conditions: 1. Biting on the oral tube of the peak flow meter and lip-sealing the tube; 2. Using a custom built diaphragm allowing the subject to lip-seal the tube of the peak flow meter without biting on it; 3. Using orange wood blocks of known dimension bilaterally on the posterior occlusion, and a custom built diaphragm allowing the subject to lip-seal the oral tube of the peak flow meter without biting on it; 4. Using a commercial single (maxillary) athletic mouthpiece and a custom built diaphragm allowing the subject to lip-seal the oral tube of the peak flow meter without biting on it; and 5. Using a commercial double (maxillary and mandibular) athletic mouthpiece and a custom built diaphragm allowing the subject to lip-seal the oral tube of the peak flow meter without biting on it. Expiratory peak flow measurements were virtually the same whether the subjects bit and lip-sealed on the oral tube of the peak flow meter, used the custom diaphragm and lip-sealed without biting on the oral tube of the peak flow meter, or bit on the orange wood blocks while using the custom diaphragm and lip-sealing without biting on the oral tube. There was significant deterioration (p < .0001) in expiratory peak flow volume when either the single or double commercial athletic mouthpieces were employed.

Для цитирования: Schwartz R, Collins B J, Fong C. Effects of a single and double commercial athletic mouthpiece on expiratory peak flow: a pilot study.. Cranio : the journal of craniomandibular practice. 2000. DOI: 10.1080/08869634.2000.11746110.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.