MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aos.12154

Медицинская библиотека · Acta ophthalmologica · 2013

Characterization of the thickness of different corneal zones in glaucoma: effect on dynamic contour, Goldmann and rebound tonometries.

Saenz-Frances Federico, Jañez Luis, Borrego-Sanz Lara, Martinez-de-la-Casa Jose Maria, Morales-Fernandez Laura, Santos-Bueso Enrique, Garcia-Sanchez Julian, Garcia-Feijoo Julian

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To characterize five models of corneal thickness circular zoning in a sample of healthy controls and a sample of patients with primary open-angle glaucoma (POAG) and to determine their effect on Goldmann (GAT), dynamic contour (DCT) and rebound tonometers (RT).

METHODS

The study participants were 122 controls and 129 cases. Five corneal thickness zoning models (A, B, C, D and E) were constructed. The partitioning pattern consisted of a circle centred at the corneal apex and several concentric rings, until the limbus; the contours of each ring followed the geometry of the corneal contour of each participant. In Model A, the central circle was 1 mm in diameter and five concentric rings were established. Mean was obtained for each zone for both samples and compared between them using a t-test. The effect on the tonometers of central cornel thickness (CCT) and mean thickness of the zones generated was determined through several linear regression models (one per tonometer and per sample).

RESULTS

According to a t-test, cases and controls differ in zones I [mean difference (MD): 17.93 μm], V (MD: 25.52 μm) and VI (MD: 31.78 μm) of model A (higher values in the cases sample). RT was affected by CCT (controls: B = 0.089; cases: B = 0.081). DCT was affected by zone IV of model A (controls: B = -0.029; cases: B = -0.012). GAT was affected by CCT (controls: B = 0.043; cases: B = 0.025) and zone III of model A (controls: B = -0.045; cases: B = -0.033).

CONCLUSION

Our results highlight the importance of the thickness of other regions of the cornea different from its main centre in discriminating between healthy controls and patients with POAG and in IOP measurements made using DCT, GAT and RT.

Для цитирования: Saenz-Frances Federico, Jañez Luis, Borrego-Sanz Lara, Martinez-de-la-Casa Jose Maria, Morales-Fernandez Laura, Santos-Bueso Enrique, Garcia-Sanchez Julian, Garcia-Feijoo Julian. Characterization of the thickness of different corneal zones in glaucoma: effect on dynamic contour, Goldmann and rebound tonometries.. Acta ophthalmologica. 2013. DOI: 10.1111/aos.12154.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.