Dynamic contour tonometry in primary open angle glaucoma and pseudoexfoliation glaucoma: factors associated with intraocular pressure and ocular pulse amplitude.

Moghimi Sasan, Torabi Hamidreza, Fakhraie Ghasem, Nassiri Nariman, Mohammadi Massood

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the intraocular pressures (IOP) and ocular pulse amplitudes (OPAs) in patients with primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PXG), and to evaluate ocular and systemic factors associated with the OPA.

MATERIALS AND

METHODS

In this prospective study, on 28 POAG and 30 PXG patients, IOP was measured with the Goldmann applanation tonometry (GAT) and the Pascal dynamic contour tonometry (DCT). Other measurements included central corneal thickness (CCT), vertical cup-to-disc ratio (CDR), and systolic and diastolic blood pressure. Statistical significance was defined as P < 0.05.

RESULTS

In each of the POAG and PXG groups, GAT IOP was correlated with CCT (r = 0.40, P = 0.03 and r = 0.35, P = 0.05, respectively), whereas DCT IOP and CCT were not correlated. In all patients and in the POAG group, OPA was positively correlated with DCT IOP (r = 0.39, P = 0.002). OPA was not correlated with CCT in the POAG (P = 0.80), nor in the PXG (P = 0.20) group, after adjusting for DCT IOP. When corrected for DCT IOP and CCT, there was a significant negative correlation between OPA and vertical CDR in all patients (r = -0.41, P = 0.002). There was no significant difference in OPA between groups (P = 0.55), even when OPA was adjusted for IOP and systolic and diastolic pressure (P = 0.40), in a linear regression model.

CONCLUSION

DCT IOP and OPA are not correlated with CCT. There is no significant difference between the OPA of PXG and POAG eyes. OPA is correlated with DCT IOP, and is lower in eyes with more advanced glaucomatous cupping.

Для цитирования: Moghimi Sasan, Torabi Hamidreza, Fakhraie Ghasem, Nassiri Nariman, Mohammadi Massood. Dynamic contour tonometry in primary open angle glaucoma and pseudoexfoliation glaucoma: factors associated with intraocular pressure and ocular pulse amplitude.. Middle East African journal of ophthalmology. 2013. DOI: 10.4103/0974-9233.110606.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.