MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fpubh.2023.1279718

Медицинская библиотека · Frontiers in public health · 2023

The accuracy of intraocular lens power calculation formulas based on artificial intelligence in highly myopic eyes: a systematic review and network meta-analysis.

Zhou Yi, Dai Minhui, Sun Lingyu, Tang Xiangyi, Zhou Ling, Tang Zhiyao, Jiang Jian, Xia Xiaobo

Систематический обзорПоддержка исследования: вне правительства СШАСтатьяNetwork Meta-AnalysisПеревод пока не подготовлен

Аннотация

OBJECTIVE

To systematically compare and rank the accuracy of AI-based intraocular lens (IOL) power calculation formulas and traditional IOL formulas in highly myopic eyes.

METHODS

We screened PubMed, Web of Science, Embase, and Cochrane Library databases for studies published from inception to April 2023. The following outcome data were collected: mean absolute error (MAE), percentage of eyes with a refractive prediction error (PE) within ±0.25, ±0.50, and ±1.00 diopters (D), and median absolute error (MedAE). The network meta-analysis was conducted by R 4.3.0 and STATA 17.0.

RESULTS

Twelve studies involving 2,430 adult myopic eyes (with axial lengths >26.0 mm) that underwent uncomplicated cataract surgery with mono-focal IOL implantation were included. The network meta-analysis of 21 formulas showed that the top three AI-based formulas, as per the surface under the cumulative ranking curve (SUCRA) values, were XGBoost, Hill-RBF, and Kane. The three formulas had the lowest MedAE and were more accurate than traditional vergence formulas, such as SRK/T, Holladay 1, Holladay 2, Haigis, and Hoffer Q regarding MAE, percentage of eyes with PE within ±0.25, ±0.50, and ±1.00 D.

CONCLUSIONS

The top AI-based formulas for calculating IOL power in highly myopic eyes were XGBoost, Hill-RBF, and Kane. They were significantly more accurate than traditional vergence formulas and ranked better than formulas with Wang-Koch AL modifications or newer generations of formulas such as Barrett and Olsen.

SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/PROSPERO/, identifier: CRD42022335969.

Для цитирования: Zhou Yi, Dai Minhui, Sun Lingyu, Tang Xiangyi, Zhou Ling, Tang Zhiyao, Jiang Jian, Xia Xiaobo. The accuracy of intraocular lens power calculation formulas based on artificial intelligence in highly myopic eyes: a systematic review and network meta-analysis.. Frontiers in public health. 2023. DOI: 10.3389/fpubh.2023.1279718.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.