BMC ophthalmology · 2023

Comparison of intraocular lens power calculation formulas in patients with a history of acute primary angle-closure attack.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kim Na Hyun, Gim Yujin, Choi Kyu-Ryong, Suh Wool, Jun Roo Min, Han Kyung Eun

Аннотация

BACKGROUND: To compare the accuracy of nine intraocular lens (IOL) power calculation formulas, including three traditional formulas (SRK/T, Haigis, and Hoffer Q) and six new-generation formulas (Barrett Universal II [BUII], Hill-Radial Basis Function [RBF] 3.0, Kane, Emmetropia verifying optical [EVO], Ladas Super, and Pearl-DGS) in patients who underwent cataract surgery after acute primary angle closure (APAC).

METHODS: In this retrospective cross-sectional study, 44 eyes of 44 patients (APAC) and 60 eyes of 60 patients (control) were included. We compared the mean absolute error, median absolute error (MedAE), and prediction error after surgery. Subgroup analyses were performed on whether axial length (AL) or preoperative laser peripheral iridotomy affected the postoperative refractive outcomes.

RESULTS: In the APAC group, all formulas showed higher MedAE and more myopic shift than the control group (all P < 0.05). In APAC eyes with AL ≥ 22 mm, there were no differences in MedAEs according to the IOL formulas; however, in APAC eyes with AL < 22 mm, Haigis (0.49 D) showed lower MedAE than SRK/T (0.82 D) (P = 0.036) and Hill-RBF 3.0 (0.54 D) showed lower MedAE than SRK/T (0.82 D), Hoffer Q (0.75 D) or Kane (0.83 D) (P = 0.045, 0.036 and 0.027, respectively). Pearl-DGS (0.63 D) showed lower MedAE than Hoffer Q (0.75 D) and Kane (0.83 D) (P = 0.045 and 0.036, respectively). Haigis and Hill-RBF 3.0 showed the highest percentage (46.7%) of eyes with PE within ± 0.5 D in APAC eyes with AL < 22 mm. Iridectomized eyes did not show superior precision than the non-iridotomized eyes in the APAC group.

CONCLUSIONS: Refractive errors in the APAC group were more myopic than those in the control group. Haigis and Hill-RBF 3.0 showed high precision in the eyes with AL < 22 mm in the APAC group.