m+Medelevator.RU
← Поиск публикаций
Brain stimulation · 2023

Cyclic versus continuous deep brain stimulation in patients with obsessive compulsive disorder: A randomized controlled trial.

Рандомизированное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Graat Ilse, van Rooijen Geeske, Prinsen Janine, Bergfeld Isidoor, Figee Martijn, Denys Damiaan, Mocking Roel

Аннотация

BACKGROUND: Deep brain stimulation (DBS) of the ventral anterior limb of the internal capsule (vALIC) is effective for refractory obsessive-compulsive disorder (OCD), but patients typically require high stimulation voltages and DBS comes with a risk for adverse events (AE).

OBJECTIVE: The aim of the present study was to advance DBS for OCD by optimizing energy efficiency and minimize adverse events using a cyclic form of stimulation METHODS: This double blind, randomized crossover trial compares 2 weeks of continuous versus cyclic DBS (0.1 s ON, 0.2 s OFF) in 16 patients with OCD. We compared OCD symptoms (Yale-Brown Obsessive-Compulsive Scale, Y-BOCS), Hamilton Depression Rating Scale (HAM-D), Hamilton Anxiety Scale (HAM-A), AEs, battery life, cognitive performance and quality of life.

RESULTS: Average Y-BOCS scores at baseline increased significantly with 5.5 points (p = 0.006) in the cyclic condition. Average HAM-D and HAM-A scores increased with 2.2 (p = 0.088) and 2.8 points (p = 0.018). The overall health scale of quality of life worsened during cyclic DBS (p = 0.044). Patients reported on average 3.3 AEs during continuous stimulation and 4.4 AEs during cyclic stimulation (p = 0.175), though stimulation-related AEs such as headache and concentration problems reduced during cyclic DBS. Battery usage during continuous DBS was 0.021 V per hour compared to 0.008 V per hour during cyclic DBS.

CONCLUSION: Though specific stimulation-related AEs improved, cyclic stimulation (0.1 s ON, 0.2 s OFF) comes with a high relapse risk in patients with DBS for OCD. Cyclic DBS is no alternative for standard DBS treatment, but applicable in case of debilitating AEs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты