m+Medelevator.RU
← Поиск публикаций
BMC ophthalmology · 2023

Relationship between myopia control and amount of corneal refractive change after orthokeratology lens treatment.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sun Lu, Song Hong-Xin, Li Zheng-Xuan, Chen Yun, He Zhi-Qiang

Аннотация

BACKGROUND: To evaluate the relationship between amount of corneal refractive change (CRC) after wearing orthokeratology (Ortho-K) lenses and axial length (AL) growth.

METHODS: We retrospectively enrolled 77 patients (77 eyes) aged 8-14 years who wore Ortho-K lenses more than 12 months. We divided the patients into 2 subgroups: spherical equivalent (SE) ≤ -3.0 D and SE > -3.0 D subgroup. The sagittal and tangential curvature maps and corneal topographic data within the 8-mm diameter ring at the baseline and during follow-up visits after wearing Ortho-K lens were recorded in addition to the area, height, and volume of the CRC region. The AL data were recorded at the baseline and during follow-up visits. Multivariate linear regression was conducted to analyze associations between the area, height, and volume of the CRC region, AL elongation, and SE.

RESULTS: The average change in the CRC region was 9.77 ± 0.60 D in height, 16.66 ± 3.61 mm2 in area, and 87.47 ± 8.96 D*mm2 in volume on the tangential diagram after wearing Ortho-K lenses for 3 months. The AL showed a change of 0.19 ± 0.14 mm after 1 year of Ortho-K lens wear (P < 0.05). At 1 year, AL elongation was negatively correlated with the area (P = 0.019) and volume (P < 0.001) of the CRC region. At 1 year, for every 1-mm2 increase in the area and every 1-D*mm2 increase in the volume of the CRC region, the average AL elongation decreased by 0.01 mm and 0.002 mm, respectively, in the multivariate analysis. In patients with SE ≤ -3.0 D, AL elongation was negatively correlated with the CRC-region volume (β = -0.002, P = 0.018), and in patients with SE > -3.0 D, AL elongation was negatively correlated with the CRC-region area (β = -0.017, P = 0.016).

CONCLUSIONS: The AL elongation-control efficacy of Ortho-K lenses may be related to the area and volume of the CRC region.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты