MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000381680

Медицинская библиотека · Stereotactic and functional neurosurgery · 2015

Aim for the Suprasternal Notch: Technical Note to Avoid Bowstringing after Deep Brain Stimulation.

Akram Harith, Limousin Patricia, Hyam Jonathan, Hariz Marwan I, Zrinzo Ludvic

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Bowstringing may occur when excessive fibrosis develops around extension cables in the neck after deep brain stimulation (DBS) surgery. Though the occurrence of this phenomenon is rare, we have noted that it tends to cause maximal discomfort when the cables cross superficially over the convexity of the clavicle. We hypothesise that bowstringing may be avoided by directing the extension cables towards the suprasternal notch.

METHODS

When connecting DBS leads to an infraclavicular pectoral implantable pulse generator (IPG), tunnelling is directed towards the suprasternal notch, before being directed laterally towards the IPG pocket. In previously operated patients with established fibrosis, the fibrous tunnel is opened and excised as far cranially as possible, allowing medial rerouting of cables. Using this approach, we reviewed our series of patients who underwent DBS surgery over 10 years.

RESULTS

In 429 patients, 7 patients (2%) with cables tunnelled over the convexity of the clavicle complaining of bowstringing underwent cable exploration and rerouting. This eliminated bowstringing and provided better cosmetic results. When the cable trajectory was initially directed towards the suprasternal notch, no bowstringing was observed.

CONCLUSION

The tunnelling trajectory appears to influence postoperative incidence of fibrosis associated with DBS cables. Modifying the surgical technique may reduce the incidence of this troublesome adverse event.

Для цитирования: Akram Harith, Limousin Patricia, Hyam Jonathan, Hariz Marwan I, Zrinzo Ludvic. Aim for the Suprasternal Notch: Technical Note to Avoid Bowstringing after Deep Brain Stimulation.. Stereotactic and functional neurosurgery. 2015. DOI: 10.1159/000381680.