MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-022-09275-4

Медицинская библиотека · European radiology · 2022

Simultaneous multislice diffusion-weighted imaging versus standard diffusion-weighted imaging in whole-body PET/MRI.

Furtado Felipe S, Mercaldo Nathaniel D, Vahle Thomas, Benkert Thomas, Bradley William R, Ratanaprasatporn Lisa, Seethamraju Ravi Teja, Harisinghani Mukesh G, Lee Susanna, Suarez-Weiss Krista, Umutlu Lale, Catana Ciprian, Pomykala Kelsey L, Domachevsky Liran, Bernstine Hanna, Groshar David, Rosen Bruse R, Catalano Onofrio Antonio

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare standard (STD-DWI) single-shot echo-planar imaging DWI and simultaneous multislice (SMS) DWI during whole-body positron emission tomography (PET)/MRI regarding acquisition time, image quality, and lesion detection.

METHODS

Eighty-three adults (47 females, 57%), median age of 64 years (IQR 52-71), were prospectively enrolled from August 2018 to March 2020. Inclusion criteria were (a) abdominal or pelvic tumors and (b) PET/MRI referral from a clinician. Patients were excluded if whole-body acquisition of STD-DWI and SMS-DWI sequences was not completed. The evaluated sequences were axial STD-DWI at b-values 50-400-800 s/mm2 and the apparent diffusion coefficient (ADC), and axial SMS-DWI at b-values 50-300-800 s/mm2 and ADC, acquired with a 3-T PET/MRI scanner. Three radiologists rated each sequence's quality on a five-point scale. Lesion detection was quantified using the anatomic MRI sequences and PET as the reference standard. Regression models were constructed to quantify the association between all imaging outcomes/scores and sequence type.

RESULTS

The median whole-body STD-DWI acquisition time was 14.8 min (IQR 14.1-16.0) versus 7.0 min (IQR 6.7-7.2) for whole-body SMS-DWI, p < 0.001. SMS-DWI image quality scores were higher than STD-DWI in the abdomen (OR 5.31, 95% CI 2.76-10.22, p < 0.001), but lower in the cervicothoracic junction (OR 0.21, 95% CI 0.10-0.43, p < 0.001). There was no significant difference in the chest, mediastinum, pelvis, and rectum. STD-DWI detected 276/352 (78%) lesions while SMS-DWI located 296/352 (84%, OR 1.46, 95% CI 1.02-2.07, p = 0.038).

CONCLUSIONS

In cancer staging and restaging, SMS-DWI abbreviates acquisition while maintaining or improving the diagnostic yield in most anatomic regions.

KEY POINTS: • Simultaneous multislice diffusion-weighted imaging enables faster whole-body image acquisition. • Simultaneous multislice diffusion-weighted imaging maintains or improves image quality when compared to single-shot echo-planar diffusion-weighted imaging in most anatomical regions. • Simultaneous multislice diffusion-weighted imaging leads to superior lesion detection.

Для цитирования: Furtado Felipe S, Mercaldo Nathaniel D, Vahle Thomas, Benkert Thomas, Bradley William R, Ratanaprasatporn Lisa, Seethamraju Ravi Teja, Harisinghani Mukesh G, Lee Susanna, Suarez-Weiss Krista, Umutlu Lale, Catana Ciprian, Pomykala Kelsey L, Domachevsky Liran, Bernstine Hanna, Groshar David, Rosen Bruse R, Catalano Onofrio Antonio. Simultaneous multislice diffusion-weighted imaging versus standard diffusion-weighted imaging in whole-body PET/MRI.. European radiology. 2022. DOI: 10.1007/s00330-022-09275-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.