Stough D B, Spencer D M, Schauder C S
Аннотация
BACKGROUND: Scalp reduction for male pattern and other extensive, permanent crown-vertex alopecias has been a beneficial, adjuvant procedure in hair replacement surgery and has been augmented by unsightly and sometimes painful intraoperative and chronic scalp expansion techniques.
METHODS: Ten patients underwent scalp reduction for male pattern baldness utilizing intraoperative Sure-Closure, a skin-stretching device. Ten patients had Frechet Extenders placed under the scalp during their scalp reductions with subsequent removal 28 days later followed immediately by second reduction procedures.
RESULTS: The skin-stretching device, Sure-Closure, allowed the excision of 20%-30% more alopecic scalp during scalp reduction than what would have been possible with scalp reduction alone. The Frechet Extender when combined with a lazy S excision pattern for scalp reduction procedures generated between 25% and 50% more excision of alopecic scalp than with scalp reduction alone.
CONCLUSION: Scalp reduction procedures can be more effectively performed with minimal complications and fewer reductions required per patient using either intraoperative scalp extension with the Sure-Closure device or chronic scalp extension with the Frechet Extender.
METHODS: Ten patients underwent scalp reduction for male pattern baldness utilizing intraoperative Sure-Closure, a skin-stretching device. Ten patients had Frechet Extenders placed under the scalp during their scalp reductions with subsequent removal 28 days later followed immediately by second reduction procedures.
RESULTS: The skin-stretching device, Sure-Closure, allowed the excision of 20%-30% more alopecic scalp during scalp reduction than what would have been possible with scalp reduction alone. The Frechet Extender when combined with a lazy S excision pattern for scalp reduction procedures generated between 25% and 50% more excision of alopecic scalp than with scalp reduction alone.
CONCLUSION: Scalp reduction procedures can be more effectively performed with minimal complications and fewer reductions required per patient using either intraoperative scalp extension with the Sure-Closure device or chronic scalp extension with the Frechet Extender.