American journal of ophthalmology · 2016
Corneal Astigmatism and Aberrations After Combined Femtosecond-Assisted Phacoemulsification and Arcuate Keratotomy: Two-Year Results.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chan Tommy C Y, Ng Alex L K, Cheng George P M, Wang Zheng, Woo Victor C P, Jhanji Vishal
Аннотация
PURPOSE: To investigate the stability of corneal astigmatism and higher-order aberrations after combined femtosecond-assisted phacoemulsification and arcuate keratotomy.
DESIGN: Retrospective, interventional case series.
METHODS: Surgery was performed using a VICTUS (Bausch & Lomb Inc, Dornach, Germany) platform. A single, 450-μm deep, arcuate keratotomy was paired at the 8-mm zone with the main phacoemulsification incision in the opposite meridian. The keratotomy incisions were not opened. Corneal astigmatism and higher-order aberration measurements obtained preoperatively and at 2 months and 2 years postoperatively were analyzed.
RESULTS: Fifty eyes of 50 patients (mean age 66.2 ± 10.5 years) were included. The mean preoperative corneal astigmatism was 1.35 ± 0.48 diopters (D). This was reduced to 0.67 ± 0.54 D at 2 months and 0.74 ± 0.53 D at 2 years postoperatively (P < .001). There was no statistically significant difference between postoperative corneal astigmatism over 2 years (P = .392). Both magnitude of error and absolute angle of error were comparable between the 2 postoperative time points (P > .283). At postoperative 2 months and 2 years, 72% and 70% of eyes were within 15 degrees of preoperative meridian of astigmatism, respectively. All wavefront measurements increased significantly at 2 months and 2 years (P < .007), except spherical aberration (P > .150). There was no significant difference in higher-order aberrations between 2 months and 2 years postoperatively (P > .486).
CONCLUSIONS: Our study showed the stability of femtosecond-assisted arcuate keratotomy. Further studies using other platforms and nomograms are needed to corroborate the findings of this study.
DESIGN: Retrospective, interventional case series.
METHODS: Surgery was performed using a VICTUS (Bausch & Lomb Inc, Dornach, Germany) platform. A single, 450-μm deep, arcuate keratotomy was paired at the 8-mm zone with the main phacoemulsification incision in the opposite meridian. The keratotomy incisions were not opened. Corneal astigmatism and higher-order aberration measurements obtained preoperatively and at 2 months and 2 years postoperatively were analyzed.
RESULTS: Fifty eyes of 50 patients (mean age 66.2 ± 10.5 years) were included. The mean preoperative corneal astigmatism was 1.35 ± 0.48 diopters (D). This was reduced to 0.67 ± 0.54 D at 2 months and 0.74 ± 0.53 D at 2 years postoperatively (P < .001). There was no statistically significant difference between postoperative corneal astigmatism over 2 years (P = .392). Both magnitude of error and absolute angle of error were comparable between the 2 postoperative time points (P > .283). At postoperative 2 months and 2 years, 72% and 70% of eyes were within 15 degrees of preoperative meridian of astigmatism, respectively. All wavefront measurements increased significantly at 2 months and 2 years (P < .007), except spherical aberration (P > .150). There was no significant difference in higher-order aberrations between 2 months and 2 years postoperatively (P > .486).
CONCLUSIONS: Our study showed the stability of femtosecond-assisted arcuate keratotomy. Further studies using other platforms and nomograms are needed to corroborate the findings of this study.