MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0301-4738.185611

Медицинская библиотека · Indian journal of ophthalmology · 2016

Wavefront aberration and contrast sensitivity after implantation of foldable and rigid iris claw phakic intraocular lenses: Artiflex versus artisan.

Parsipour Faroogh, Razmju Hassan, Khatavi Fatima, Panahi Maryam, Nouralishahi Alireza, Peyman Alireza

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIM OF STUDY: The aim of this study is to assess wavefront aberration and contrast sensitivity (CS) after implantation of foldable iris claw - artiflex- and rigid iris claw - artisan- phakic intraocular lenses (pIOLs).

MATERIALS AND

METHODS

A nonrandomized prospective comparative case study was performed on 57 eyes; of which, 54 were myopia and 3 were hyperopia. Twenty-four patients had artisan pIOL implantation and 33 had artiflex pIOL implantation. Higher-order aberration (HOA) and CS were obtained 1 year after surgery.

RESULTS

Total HOA in artisan group was greater than artiflex group (P = 0.044) with a mean HOA of 0.44 ± 0.15 root mean square (RMS) for artisan and 0.35 ± 0.15 RMS for artiflex. Although, there were no significant differences in the vertical trefoil, vertical coma, horizontal trefoil, horizontal coma, secondary astigmatism, quatrefoil, and fourth order spherical aberration in two groups. CS in mesopic conditions was better in artiflex-treated eyes at three spatial frequencies of 6, 12, and 18 cycles per degree (cpd) (P = 0.003, P = 0.007, and P = 0.00, respectively), and no significant difference was seen between two lenses at 3 cpd.

CONCLUSION

Although the components of HOA were not significantly different between two groups, total HOA was higher in artisan group, which may be due to the slight differences in each component, increasing the HOA as a total. CS was significantly better in artiflex group.

Для цитирования: Parsipour Faroogh, Razmju Hassan, Khatavi Fatima, Panahi Maryam, Nouralishahi Alireza, Peyman Alireza. Wavefront aberration and contrast sensitivity after implantation of foldable and rigid iris claw phakic intraocular lenses: Artiflex versus artisan.. Indian journal of ophthalmology. 2016. DOI: 10.4103/0301-4738.185611.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.