Assessment of subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL) implantation.
Аннотация
PURPOSE: To evaluate the subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL, STAAR Surgical) implantation.
METHODS
We prospectively examined 29 eyes of 29 consecutive patients (15 men and 14 women; ages, 37.2 ± 8.8 years) undergoing Hole ICL implantation. We assessed the values of the logarithmic straylight value [log (s)] using a straylight meter (C-Quant™ , Oculus) preoperatively and 3 months postoperatively. The patients completed a questionnaire detailing symptoms on a quantitative grading scale (National Eye Institute Refractive Error Quality of Life Instrument-42; NEI RQL-42) 3 months postoperatively. We compared the preoperative and postoperative values of the log(s) and evaluated the correlation of these values with patient subjective symptoms.
RESULTS
The mean log(s) was not significantly changed, from 1.07 ± 0.20 preoperatively, to 1.06 ± 0.17 postoperatively (Wilcoxon signed-rank test, p = 0.641). There was a significant correlation between the preoperative and postoperative log(s) (Spearman's correlation coefficient r = 0.695, p < 0.001). The postoperative log(s) was significantly associated with the scores of glare in the questionnaire (Spearman's correlation coefficient r = -0.575, p = 0.017).
CONCLUSIONS
According to our experience, Hole ICL implantation does not induce a significant additional change in the subjective intraocular forward scattering. The symptom of glare after Hole ICL implantation was significantly correlated with the postoperative intraocular forward scattering in relation to the preoperative one.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.