DOI 10.1007/s10792-016-0274-8

Медицинская библиотека · International ophthalmology · 2016

Comparison of keratometric measurements obtained by the Verion Image Guided System with optical biometry and auto-keratorefractometer.

Asena Leyla, Güngör Sirel Gür, Akman Ahmet

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

The aim of this study was to compare the keratometric measurements of Verion Image Guided System with an optical biometer (Zeiss IOLMaster 500, Carl Zeiss Meditec, Jena, Germany) and an automated keratorefractometer (AKR) (Topcon KR-8900, Topcon, Japan). In this prospective clinical trial, the right eyes of 52 patients with cataract were examined (mean age 62.25 ± 12.16 years). The measurements were taken by the three systems in a random order. Keratometric data, magnitude of astigmatism, and astigmatic axis measurements from all three instruments were compared. The results were evaluated using, intraclass correlation coefficients (ICC), Bland-Altman plots, and paired samples t tests. The mean flat/steep K of Verion, IOLMaster, and AKR were 43.22 ± 1.38D/44.23 ± 1.46D, 43.07 ± 1.26D/44.05 ± 1.34D, and 43.07 ± 1.31D/43.89 ± 1.42D, respectively. Flat K readings of Verion were higher than IOLMaster and AKR (p < 0.05 for both). Steep K readings were different for all three (p < 0.05). The magnitude of astigmatism by Verion and IOLMaster were 0.98 ± 0.65D and 0.98 ± 0.59D (p = 0.88). The mean astigmatism measured by the AKR was 0.82 ± 0.62D, less than the other two instruments (p < 0.001). Astigmatic axis measurements of Verion and AKR differed <10° in 38, between 10° and 20° in 5, and >20° in 9 eyes; the same difference was 30, 11, and 11 eyes, respectively, between Verion and IOLMaster. Although, keratometric and astigmatic results obtained from Verion were not completely interchangeable with IOLMaster and AKR, especially the agreement between Verion and IOLMaster was excellent with ICCs close to one. However, there were pronounced astigmatic axis measurement differences between three instruments.

Для цитирования: Asena Leyla, Güngör Sirel Gür, Akman Ahmet. Comparison of keratometric measurements obtained by the Verion Image Guided System with optical biometry and auto-keratorefractometer.. International ophthalmology. 2016. DOI: 10.1007/s10792-016-0274-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.