Efficacy and safety of iris-supported phakic lenses (Verisyse) for treating moderately high myopia.

Ahmedbegović Pjano Melisa, Alikadić-Husović Amila, Grišević Senad, Pašalić Adis, Pidro Ajla, Ratković Mirko, Bohač Maja, Gabrić Nikica, Gojak Refet

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIM: To evaluate efficacy and safety of iris-supported phakic lenses (Verisyse) for treating moderately high myopia.

METHODS

This prospective clinical study included 40 eyes from 29 patients, who underwent implantation of Verisyse for correction of myopia from -6.00 to -14.50 diopters (D) in the Eye Clinic ''Svjetlost'', Sarajevo, from January 2011 to January 2014. Uncorrected distance visual acuity (UDVA), manifest residual spherical equivalent(MRSE), postoperative astigmatism, intraocular pressure(IOP), endothelial cell (EC) density were evaluated at one, three, six and twelve months. Corrected visual acuity (CDVA), index of safety and efficacy were evaluated after 12 months.

RESULTS

Out of 29 patients 15 were males and 14 females, with mean age of 27.9 ± 5.0. After 12 months 77.5% eyes had UDVA ≥ 0.5 and 32.5% had UDVA ≥ 0.8. Mean MRSE was 0.55D ±0.57D and mean postoperative astigmatism -0.86D ± 0.47D. Efficacy index was 1.09 ± 0.19 and safety index 1.18 ± 0.21. One eye(2.5%) lost two Snellen lines and three eyes (7.5%) one line, 11 eyes (27.5%) gained one line, and five eyes (15.5%) gained two lines. EC loss after 12 months was 7.59 ± 3.05%. There was no significant change of IOP after one year follow up.

CONCLUSION

Implantation of iris-supported phakic lenses (Verisyse) for treating moderately high myopia is an efficient and safe procedure.

Для цитирования: Ahmedbegović Pjano Melisa, Alikadić-Husović Amila, Grišević Senad, Pašalić Adis, Pidro Ajla, Ratković Mirko, Bohač Maja, Gabrić Nikica, Gojak Refet. Efficacy and safety of iris-supported phakic lenses (Verisyse) for treating moderately high myopia.. Medicinski glasnik : official publication of the Medical Association of Zenica-Doboj Canton, Bosnia and Herzegovina. 2016. DOI: 10.17392/826-16.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.