Echocardiography (Mount Kisco, N.Y.) · 2012
The impact of mitral stenosis on left atrial function assessed by two-dimensional speckle tracking echocardiography.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Demirkol Sait, Kucuk Ugur, Baysan Oben, Balta Sevket, Celik Turgay, Kurt Ibrahim Halil, Kucuk Hilal Olgun, Yuksel Uygar Cagdas, Unlu Murat, Yokusoglu Mehmet
Аннотация
AIMS: The aim of this study is to investigate the effect of mitral stenosis (MS) on left atrial (LA) function using two-dimensional speckle tracking echocardiography (2DSTE).
METHODS AND RESULTS: The study subjects consisted of 52 patients with asymptomatic MS and 52 control subjects. LA function was assessed using prototype speckle tracking software and manual tracking method. Maximal LA volume (LAVmax) and minimal LA volume (LAVmin) and LA volume before atrial contraction (LAVpre-a) were measured. Using these volumes, LA reservoir, conduit and booster pump fuction parameters were calculated. Indexed LAVmax, LAVmin, and LAVpre-a measurements via speckle tracking were highly correlated with manual tracing methods in both groups. Expansion index (67.8 ± 36.4 vs. 148.3 ± 44.2), diastolic emptying index (37.7 ± 12.9 vs. 58.0 ± 8.5), passive emptying (37.3 ± 14.1 vs. 70.4 ± 10.4) and passive emptying index (13.3 ± 6.3 vs. 41.3 ± 10.6) were decreased significantly in MS patients (P < 0.001). In contrast active emptying index (62.6 ± 4.1 vs. 29.5 ± 10.1) increased in MS group (P < 0.001) while active emptying (28.1 ± 13.0 vs. 28.3 ± 6.9) remained same among both groups.
CONCLUSIONS: This is the first study relating LA volumes and function assessed by 2DSTE to MS. 2D speckle tracking analysis of LA volume is relatively easy and provides more detailed information regarding the changes in LA volumes during the cardiac cycle.
METHODS AND RESULTS: The study subjects consisted of 52 patients with asymptomatic MS and 52 control subjects. LA function was assessed using prototype speckle tracking software and manual tracking method. Maximal LA volume (LAVmax) and minimal LA volume (LAVmin) and LA volume before atrial contraction (LAVpre-a) were measured. Using these volumes, LA reservoir, conduit and booster pump fuction parameters were calculated. Indexed LAVmax, LAVmin, and LAVpre-a measurements via speckle tracking were highly correlated with manual tracing methods in both groups. Expansion index (67.8 ± 36.4 vs. 148.3 ± 44.2), diastolic emptying index (37.7 ± 12.9 vs. 58.0 ± 8.5), passive emptying (37.3 ± 14.1 vs. 70.4 ± 10.4) and passive emptying index (13.3 ± 6.3 vs. 41.3 ± 10.6) were decreased significantly in MS patients (P < 0.001). In contrast active emptying index (62.6 ± 4.1 vs. 29.5 ± 10.1) increased in MS group (P < 0.001) while active emptying (28.1 ± 13.0 vs. 28.3 ± 6.9) remained same among both groups.
CONCLUSIONS: This is the first study relating LA volumes and function assessed by 2DSTE to MS. 2D speckle tracking analysis of LA volume is relatively easy and provides more detailed information regarding the changes in LA volumes during the cardiac cycle.