MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1748-6041/3/2/025011

Медицинская библиотека · Biomedical materials (Bristol, England) · 2008

The biocompatibility of SLA-treated titanium implants.

Kim Hyeongil, Choi Seong-Ho, Ryu Jae-Jun, Koh Seung-Yong, Park Ju-Han, Lee In-Seop

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The titanium implant surface was sandblasted with large grits and acid etched (SLA) to increase the implant surface for osseointegration. The topography of the titanium surface was investigated with scanning electron microscopy (SEM) and a profilometer. The SLA implant demonstrated uniform small micro pits (1-2 microm in diameter). The values of average roughness (R(a)) and maximum height (R(t)) were 1.19 microm and 10.53 microm respectively after sandblasting and the acid-etching treatment. In the cell-surface interaction study, the human osteoblast cells grew well in vitro. The in vivo evaluation of the SLA implant placed in rabbit tibia showed good bone-to-implant contact (BIC) with a mean value of 29% in total length of the implant. In the short-term clinical study, SLA implants demonstrated good clinical performance, maintaining good crestal bone height.

Для цитирования: Kim Hyeongil, Choi Seong-Ho, Ryu Jae-Jun, Koh Seung-Yong, Park Ju-Han, Lee In-Seop. The biocompatibility of SLA-treated titanium implants.. Biomedical materials (Bristol, England). 2008. DOI: 10.1088/1748-6041/3/2/025011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.