DOI 10.1016/j.ejrad.2003.08.006

Медицинская библиотека · European journal of radiology · 2004

MRI evaluation of patellar tendon defect after harvesting its central third.

Koseoglu Kutsi, Memis Aysenur, Argin Mehmet, Arkun Remide

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: the purpose of this study was to evaluate defect width of patellar tendon after harvest for anterior cruciate ligament reconstruction.

MATERIALS AND

METHODS

we performed MRI at various time interval after graft harvest (2-96 months) on 28 patients who had had reconstruction of the anterior cruciate ligament using mid-third patellar tendon. T1 and T2 weighted axial images were obtained to assess donor site defect of the patellar tendon. Measurement of the defect width was performed at the level of menisci on the axial images. The patients were divided into two groups according to the time interval between operation and imaging. The defect width of patients with short time interval (2-12 months) was compared to the defect width of patients with long time interval (12-96 months).

RESULTS

the average defect width of patients with short time interval was 6.4 mm and it was 2.2 mm for the patients with long time interval. Decreased defect width was obtained from MRI images in the patients with long time interval. Closed donor site defect was detected in 1 out of 14 patients with short time interval and 6 out of 14 patients with long time interval.

DISCUSSION AND

CONCLUSION

these results show that there is no complete closure of donor site defect up to 1 year. However, it seems to be nearly complete closure of patellar tendon defect in the long time period.

Для цитирования: Koseoglu Kutsi, Memis Aysenur, Argin Mehmet, Arkun Remide. MRI evaluation of patellar tendon defect after harvesting its central third.. European journal of radiology. 2004. DOI: 10.1016/j.ejrad.2003.08.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.