DOI 10.23736/s2724-5683.22.06185-3
Impact of acute and persistent stent malapposition after percutaneous coronary intervention on adverse cardiovascular outcomes.
Аннотация
INTRODUCTION
The association of coronary stent malapposition (SM) and adverse clinical outcomes after percutaneous coronary intervention (PCI) remains unclear. We aimed to perform a systematic review and meta-analysis of randomized and observational studies to assess the association between acute and persistent SM detected using intravascular ultrasound (IVUS) or optical coherence tomography (OCT) and adverse cardiovascular outcomes.
EVIDENCE ACQUISITION: Available studies were identified through a systematic search of PubMed, reference lists of relevant articles, and Medline. Main efficacy outcomes of interest were: device-oriented composite endpoint (DoCE, including cardiac death, myocardial infarction [MI], target lesion revascularization [TLR], and stent thrombosis [ST]), major safety events (MSE, including cardiac death, MI and ST), TLR, and ST. A sensitivity analysis regarding the impact of major malapposition was also performed.
EVIDENCE SYNTHESIS: A total of 9 studies enrolling 6497 patients were included in the meta-analysis. After a mean follow-up of 24±14 months, overall acute and/or persistent malapposition was not significantly associated with the occurrence of all the outcomes of interest, including DoCE (risk ratio [RR] 1.00, 95% confidence interval [CI, 0.79-1.26], P=0.99), MSE (RR 1.42, 95%CI [0.81-2.50], P=0.22), TLR (RR 0.84, 95%CI [0.59-1.19], P=0.33), and ST (RR 1.16, 95%CI [0.48-2.85], P=0.74). In the sensitivity analysis, we found a significant increase of MSE in patients with major malapposition (RR 2.97, 95%CI [1.51-5.87], P=0.001).
CONCLUSIONS
Acute and persistent SM were not overall associated with adverse cardiovascular clinical outcomes at follow-up. However, major malapposition was associated with an increased risk of major safety events, including cardiac death, MI and ST. These findings should be taken into account during stent implantation and PCI optimization.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.