Nakano Takayuki, Ikenaga Hiroki, Takeda Atsushi, Morita Yuichi, Higashihara Tasuku, Watanabe Noriaki, Sada Yoshiharu, Nakano Yukiko
Аннотация
BACKGROUND: Excimer laser coronary angioplasty (ELCA) has been reported to be a safe and effective atherectomy device in percutaneous coronary intervention (PCI). However, thrombotic complications after ELCA have been occasionally observed. In this study, we evaluated the impact of attenuated plaque on thrombus formation and transient no-reflow after ELCA.
METHODS: This study enrolled 58 lesions in 56 patients who underwent PCI with ELCA. It was a retrospective observational study at a single center. All lesions were imaged by intravascular ultrasound (IVUS) before and immediately after ELCA. On the plaque with ultrasound attenuation, attenuation angle per millimeter and attenuation length were measured. ELCA-induced thrombus was detected by IVUS, and transient no-reflow after ELCA was recorded.
RESULTS: Thrombus was detected in 14 lesions (30 %), and transient no-reflow occurred in 3 lesions (5 %). Lesions with thrombus had a higher mean attenuation angle (median [interquartile range] 142° [112°-152°] vs. 64° [0°-115°]; p = 0.001), maximum attenuation angle (209° [174°-262°] vs. 86° [0°-173°]; p < 0.001), and longer attenuation length (12 mm [8 mm-17 mm] vs. 2 mm [0 mm-5 mm]; p < 0.001). Lesions with thrombus leading to transient no-reflow had a longer lipid length and a significantly higher troponin I level after PCI.
CONCLUSIONS: IVUS-identified attenuated plaque was strongly correlated with ELCA-induced thrombus. Furthermore, attenuation length may predict transient no-reflow.
METHODS: This study enrolled 58 lesions in 56 patients who underwent PCI with ELCA. It was a retrospective observational study at a single center. All lesions were imaged by intravascular ultrasound (IVUS) before and immediately after ELCA. On the plaque with ultrasound attenuation, attenuation angle per millimeter and attenuation length were measured. ELCA-induced thrombus was detected by IVUS, and transient no-reflow after ELCA was recorded.
RESULTS: Thrombus was detected in 14 lesions (30 %), and transient no-reflow occurred in 3 lesions (5 %). Lesions with thrombus had a higher mean attenuation angle (median [interquartile range] 142° [112°-152°] vs. 64° [0°-115°]; p = 0.001), maximum attenuation angle (209° [174°-262°] vs. 86° [0°-173°]; p < 0.001), and longer attenuation length (12 mm [8 mm-17 mm] vs. 2 mm [0 mm-5 mm]; p < 0.001). Lesions with thrombus leading to transient no-reflow had a longer lipid length and a significantly higher troponin I level after PCI.
CONCLUSIONS: IVUS-identified attenuated plaque was strongly correlated with ELCA-induced thrombus. Furthermore, attenuation length may predict transient no-reflow.