MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejcts.2010.12.068

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2011

Clinical experience with the ATS 3f Enable® Sutureless Bioprosthesis.

Martens Sven, Sadowski Jerzy, Eckstein Friedrich S, Bartus Krzysztof, Kapelak Boguslaw, Sievers Hans-Hinrich, Schlensak Christian, Carrel Thierry

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

The ATS 3f Enable® Bioprosthesis is a self-expanding valve with a tubular design that allows for decreased leaflet stress and preservation of aortic sinuses. We report the midterm results of a prospective, multicenter clinical study evaluating the safety and efficacy of this stented bioprosthesis in patients undergoing isolated aortic valve replacement with or without concomitant procedures.

METHODS

A total of 140 patients (mean age: 76 ± 6 years; 63% of patients in New York Heart Association (NYHA) stage III-IV) received the ATS 3f Enable(®) Bioprosthesis in 10 European centers between March 2007 and December 2009. The total accumulated follow-up is 121.8 patient-years.

RESULTS

Valve implantation resulted in significant improvement of patients' symptoms. Mean systolic gradient was 9.04 ± 3.56 and 8.62 ± 3.16 mm Hg with mean effective orifice area of 1.69 ± 0.52 and 1.67 ± 0.44 at 6 months and 1 year, respectively. No significant transvalvular aortic regurgitation was observed. Early complications included three major paravalvular leaks (PVL; 2.1%) resulting in valve explantation and one thrombo-embolic (0.7%) event. All, but one, of the early PVLs were evident intra-operatively with the medical decision made not to reposition or resolve immediately. Late adverse events included three explantations (2.5% per patient-year): one due to PVL and two due to endocarditis. There was an additional case of late endocarditis (0.8% per patient-year) that resolved by medical management. No structural deterioration, valve-related thrombosis or hemolysis was documented.

CONCLUSIONS

The sutureless valve implantation technique is feasible and safe with the ATS 3f Enable Bioprosthesis. Valve implantation resulted in excellent hemodynamics and significant clinical improvement. Overall, these data confirm the safety and clinical utility of the Enable® Bioprosthesis for aortic valve replacement.

Для цитирования: Martens Sven, Sadowski Jerzy, Eckstein Friedrich S, Bartus Krzysztof, Kapelak Boguslaw, Sievers Hans-Hinrich, Schlensak Christian, Carrel Thierry. Clinical experience with the ATS 3f Enable® Sutureless Bioprosthesis.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2011. DOI: 10.1016/j.ejcts.2010.12.068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.