MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s465837

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2024

Automated Capsular Decompression to Avoid Argentinian Flag Sign in Intumescent Cataract.

Antunes Victor Andrighetti Coronado, Rosatelli Neto José de Mello, Moscovici Bernardo Kaplan, Rabelo Daniel Filipe Oliveira, Sano Victor Akio, Hida Richard Yudi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We describe an alternative automated technique that consists of simultaneous anterior capsule puncture and decompression of the capsular bag by using an insulin needle attached to the aspiration tubing of the phacoemulsification device to prevent the occurrence of the "Argentinian Flag sign" during capsulorhexis in intumescent cataract.

SETTING

Instituto de Olhos de Assis and Center of Specialties Hoftalmed, located in the state of São Paulo, Brazil.

DESIGN

Prospective interventional study.

METHODS

Eighty-eight eyes of 88 patients with white or intumescent cataracts were included in this study. Routine clear cornea incision, capsule staining with trypan blue, intracameral anesthesia, and ophthalmic viscoelastic device were used before the procedure. A 26-gauge needle was connected to the phacoemulsification aspiration tubing using a double male Luer connector for irrigation, and aspiration was inserted into the anterior chamber through a new paracentesis incision with the bevel facing down. Immediately after insertion, automated aspiration of the liquefied cortex was performed to remove anterior intralenticular material and achieve capsular decompression. Compression of the nucleus with the needle tip was performed to remove any liquefied material trapped between the posterior surface of the nucleus and the posterior capsule. All surgeries were performed using the same phacoemulsification and parameters. The rate of complete continuous capsulorhexis was observed and noted.

RESULTS

No complications were observed in any of the cases. A single-stage, continuous, and well-centered capsulorhexis was achieved in 100% of cases.

CONCLUSION

We conclude that a simultaneous puncture and decompression of the capsular bag using an insulin needle attached to the aspiration tubing of the phacoemulsification machine effectively avoided the "Argentinian Flag sign" in intumescent cataract surgery.

Для цитирования: Antunes Victor Andrighetti Coronado, Rosatelli Neto José de Mello, Moscovici Bernardo Kaplan, Rabelo Daniel Filipe Oliveira, Sano Victor Akio, Hida Richard Yudi. Automated Capsular Decompression to Avoid Argentinian Flag Sign in Intumescent Cataract.. Clinical ophthalmology (Auckland, N.Z.). 2024. DOI: 10.2147/opth.s465837.