Analysis of the ESCRS calculator's prediction accuracy.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sorkin Nir, Zadok Rotem, Totah Hashem, Savini Giacomo, Ribeiro Filomena, Findl Oliver, Buonsanti Dante, Raimundo Miguel, Abulafia Adi

Аннотация

PURPOSE: To evaluate prediction accuracy of formulas included in the ESCRS online intraocular lens (IOL) calculator using standard keratometry (K) or total keratometry (TK).

SETTING: Hospital-based academic practice.

DESIGN: Retrospective case-series.

METHODS: 523 patients with cataract (523 eyes) were included in this study. The outcome measures were trimmed means of the spherical equivalent prediction error (SEQ-PE, trueness), precision and absolute SEQ-PE (accuracy) of all 7 formulas available on the ESCRS online IOL calculator, as well as mean (Mean-All) and median (Median-All) of the predicted SEQ refraction of all formulas. Subgroup analyses evaluated the effect of axial length on formula accuracy.

RESULTS: Trimmed-mean SEQ-PE range of all formulas varied from -0.075 to +0.071 diopters (D) for K-based and from -0.003 to +0.147 D for TK-based calculations, with TK-based being more hyperopic in all formulas ( P < .001). Precision ranged from 0.210 to 0.244 D for both K-based and TK-based calculations. Absolute SEQ-PE ranged from 0.211 to 0.239 D for K-based and from 0.218 to 0.255 D for TK-based calculations. All formulas, including Mean-All and Median-All, showed high accuracy, with 84% to 90% of eyes having SEQ-PEs within 0.50 D.Myopic trimmed-mean SEQ-PEs significantly different from zero were observed in long eyes for Pearl DGS (-0.110 D, P = .005), Hill RBF (-0.120 D, P < .001), and Hoffer QST (-0.143 D, P = .001) and in short eyes for EVO 2.0 (-0.252 D, P = .001), Kane (-0.264 D, P = .001), Hoffer QST (-0.302 D, P < .001), Mean-All (-0.122 D, P = .038), and Median-All (-0.125 D, P = .043).

CONCLUSIONS: Prediction accuracy of all ESCRS IOL calculator formulas was high and globally comparable. TK-based calculations did not increase prediction accuracy and tended toward hyperopia. Observations indicating formula superiority in long and short eyes merit further evaluation.