Dual-Scan Photoacoustic Tomography for the Imaging of Vascular Structure on Foot.

Huang Chuqin, Cheng Yanda, Zheng Wenhan, Bing Robert W, Zhang Huijuan, Komornicki Isabel, Harris Linda M, Arany Praveen R, Chakraborty Saptarshi, Zhou Qifa, Xu Wenyao, Xia Jun

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

Chronic leg ulcers are affecting approximately 6.5 million Americans, and they are associated with significant mortality, reduced quality of life, and high treatment costs. Since many chronic ulcers have underlying vascular insufficiency, accurate assessment of tissue perfusion is critical to treatment planning and monitoring. This study introduces a dual-scan photoacoustic (PA) tomography (PAT) system that can simultaneously image the dorsal and plantar sides of the foot to reduce imaging time. To account for the unique shape of the foot, the system employs height-adjustable and articulating baseball stages that can scan along the foot's contour. In vivo results from healthy volunteers demonstrate the system's ability to acquire clear images of foot vasculature, and results from patients indicate that the system can image patients with various ulcer conditions. We also investigated various PA features and examined their correlation with the foot condition. Our preliminary results indicate that vessel sharpness, occupancy, intensity, and density could all be used to assess tissue perfusion. This research demonstrated the potential of PAT for routine clinical tissue perfusion assessment.

Для цитирования: Huang Chuqin, Cheng Yanda, Zheng Wenhan, Bing Robert W, Zhang Huijuan, Komornicki Isabel, Harris Linda M, Arany Praveen R, Chakraborty Saptarshi, Zhou Qifa, Xu Wenyao, Xia Jun. Dual-Scan Photoacoustic Tomography for the Imaging of Vascular Structure on Foot.. IEEE transactions on ultrasonics, ferroelectrics, and frequency control. 2023. DOI: 10.1109/tuffc.2023.3283139.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.