MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/sjopt.sjopt_37_24

Медицинская библиотека · Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society · 2024

Comparison between two-hole-assisted phaco-chop and stop-and-chop techniques for nuclear disassembly in residents' cataract surgery.

Naqaish Rehan, Alrawashdeh Hamzeh M, Sabih Rayyan, Naqvi Syed A H, Osama Muhammad, Sohail Salman, Niazi Manahil

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to evaluate the safety of the novel two-hole-assisted phaco-chop technique as a transition between stop-and-chop and direct-chop techniques and to compare its phacoemulsification parameters with the stop-and-chop technique.

METHODS

A prospective quasi-experimental study was conducted at Al-Shifa Trust Eye Hospital, Rawalpindi, Pakistan. One hundred and three patients (103 eyes), aged 18 years and above, with nuclear sclerosis (NS)+2, NS +3, +4, cortical, and posterior subcapsular cataracts (WHO Cataract Grading Group) were included, whereas patients with uveitis, glaucoma, traumatic cataracts, small pupils, zonular weakness, lens subluxation, small palpebral fissures, soft cataracts (NS + 1), and posterior polar cataracts were excluded from the study. The stop-and-chop technique was performed in 58 (56.3%) patients, whereas the two-hole-assisted chop technique in the rest. Ultrasound time (UST), total surgical time, and volume of balanced salt solution (BSS) delivered were recorded.

RESULTS

The mean age of the participants was 65.12 ± 8.85 years. The comparison of the two techniques revealed no statistically significant difference in the UST (P = 0.723), volume of BSS used (P = 0.102), and total surgery time (P = 0.517). However, a significant positive correlation between cataract grade and UST (Spearman's r = 0.888, P < 0.001), BSS volume delivered (Spearman's r = 0.831, P < 0.001), and surgery time (Spearman's r = 0.846, P < 0.001) was observed. Moreover, the UST comparison between cataract grades revealed a significant difference between the three groups (F = 185.09 P < 0.001). P < 0.05 was considered statistically significant.

CONCLUSION

The two-hole-assisted phaco chop is a safe and efficient transitional technique between stop-and-chop and direct-chop techniques for nuclear disassembly in cataract surgery performed by resident surgeons. In addition, the phacoemulsification parameters of the two-hole-assisted chop technique are comparable with the stop-and-chop technique.

Для цитирования: Naqaish Rehan, Alrawashdeh Hamzeh M, Sabih Rayyan, Naqvi Syed A H, Osama Muhammad, Sohail Salman, Niazi Manahil. Comparison between two-hole-assisted phaco-chop and stop-and-chop techniques for nuclear disassembly in residents' cataract surgery.. Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society. 2024. DOI: 10.4103/sjopt.sjopt_37_24.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.