MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s464586

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2024

Visual Outcomes and Patient Satisfaction of Trifocal or Trifocal Toric IOLs in Chinese Cataract Patients: Focus on Near Vision at 33 cm.

Cao Xinfang, Shao Jie, Zhang Yonggang, Zheng Li, Zhang Jun

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To examine the visual outcomes, particularly at 33 cm, and assess patient satisfaction following the implantation of a diffractive trifocal intraocular lens (IOL) and its toric variant.

PATIENTS AND

METHODS

This prospective single-arm observational study involved 45 Chinese patients (90 eyes) underwent bilateral cataract surgery and PanOptix or PanOptix toric intraocular lenses (IOLs) implantation. Postoperatively, visual acuity was evaluated at various distances, including 40 cm and 33 cm, for both monocular and binocular outcomes. Patient satisfaction was evaluated using the VF-14 questionnaire.

RESULTS

72 eyes underwent PanOptix IOLs implantation, and 18 eyes received PanOptix toric IOLs. At 3-month postoperative mark, the mean monocular UDVA, UIVA, and UNVA at 40 cm and 33 cm were -0.02±0.09, 0.00±0.07, 0.02±0.07, and 0.07±0.14 logMAR, respectively, with proportions of visual acuity exceeding 0.1 logMAR were 96.7%, 96.7%, 94.4%, and 74.4%, respectively. The mean binocular UDVA, UIVA, and UNVA at 40 cm and 33 cm were -0.05±0.06, -0.03±0.05, 0.00±0.05, and 0.04±0.07 logMAR, respectively, with proportions of visual acuity exceeding 0.1 logMAR were 97.8%, 100.0%, 100.0%, and 91.1%, respectively. When the near point shifted from 40cm to 33cm, some patients showed a decline for UDVA, but the average reduction was less than one line. The overall VF-14 questionnaire score was 4.02±4.19.

CONCLUSION

PanOptix can provide Chinese patients with a full range of satisfying visual acuity, near to 33cm. Though the visual acuity of some patients at 33 cm did not match the level at 40 cm, the gap of one line may not carry clinical significant.

Для цитирования: Cao Xinfang, Shao Jie, Zhang Yonggang, Zheng Li, Zhang Jun. Visual Outcomes and Patient Satisfaction of Trifocal or Trifocal Toric IOLs in Chinese Cataract Patients: Focus on Near Vision at 33 cm.. Clinical ophthalmology (Auckland, N.Z.). 2024. DOI: 10.2147/opth.s464586.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.