MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2001

[Comparative study of microvascular anastomotic clips and suture in small vessel anastomosis].

Song J X, Guo E T

Сравнительное исследованиеАннотация на английскомСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To explore an ideal way of small vessel anastomosis for microsurgery.

METHODS

Anastomosis of both carotid arteries were performed in 20 rabbits. One side of the arteries were anastomosed with anastomotic clips, the other side of the arteries, as comparison, were anastomosed with suture. The vessels were harvested at first and 14th day after operation and were evaluated using operating microscope, light microscope and electronic microscope.

RESULTS

The average anastomotic time for suture was about 15 minutes, while for the clips was 2 to 5 minutes. There were no difference in patency between the two techniques. Endothelialization at the anastomotic sites were both completed 14 days postoperatively. However, for the anastomotic clips, there were no endothelia damage and foreign bodies formation inside the vessels.

CONCLUSION

This experiment has confirmed that the anastomotic clip's procedure provides a very safe and easy way to perform anastomosis and reduce the incidence of thromboses.

Для цитирования: Song J X, Guo E T. [Comparative study of microvascular anastomotic clips and suture in small vessel anastomosis].. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery. 2001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.